Suppr超能文献

两种评估儿童六项活动期间身体活动能量消耗的方法比较。

Comparison of two methods to assess PAEE during six activities in children.

作者信息

Corder Kirsten, Brage Søren, Mattocks Calum, Ness Andy, Riddoch Chris, Wareham Nicholas J, Ekelund Ulf

机构信息

1MRC Epidemiology Unit, Cambridge, United Kingdom.

出版信息

Med Sci Sports Exerc. 2007 Dec;39(12):2180-8. doi: 10.1249/mss.0b013e318150dff8.

Abstract

PURPOSE

The purpose of this study was to compare the accuracy of physical activity energy expenditure (PAEE)-prediction models using accelerometry alone (ACC) and accelerometry combined with heart rate monitoring (HR+ACC) to estimate PAEE during six common activities in children (lying, sitting, slow and brisk walking, hop-scotch, running). Three PAEE-prediction models derived using the current data, and five previously published prediction models were cross-validated to estimate PAEE in this sample.

METHODS

PAEE was assessed using ACC, HR+ACC, and indirect calorimetry during six activities in 145 children (12.4 +/- 0.2 yr). One ACC and two HR+ACC PAEE-prediction models were derived using linear regression on data from the current study. These three new models were cross-validated using a jackknife approach, and a modified Bland-Altman method was used to assess the validity of all eight models.

RESULTS

PAEE predictions using the one ACC and two HR+ACC models derived in the current study correlated strongly with measured values (RMSE = 97.3-118.0 J.min.kg). All five previously published models agreed well overall (RMSE = 115.6-245.3 J.min.kg), but systematic error was present for most of these, to a greater extent for ACC.

CONCLUSIONS

ACC and HR+ACC can both be used to predict overall PAEE during these six activities in children; however, systematic error was present in all predictions. Although both ACC and HR+ACC provide accurate predictions of overall PAEE, according to the activities in this study, PAEE-prediction models using HR+ACC may be more accurate and widely applicable than those based on accelerometry alone.

摘要

目的

本研究旨在比较仅使用加速度计(ACC)以及加速度计结合心率监测(HR + ACC)来估计儿童六种常见活动(躺卧、坐着、慢走和快走、跳房子、跑步)期间身体活动能量消耗(PAEE)的预测模型的准确性。使用当前数据推导的三个PAEE预测模型以及五个先前发表的预测模型进行交叉验证,以估计该样本中的PAEE。

方法

在145名儿童(12.4±0.2岁)进行六种活动期间,使用ACC、HR + ACC和间接量热法评估PAEE。使用本研究数据通过线性回归推导一个ACC和两个HR + ACC的PAEE预测模型。这三个新模型采用留一法进行交叉验证,并使用改良的布兰德 - 奥特曼方法评估所有八个模型的有效性。

结果

使用本研究推导的一个ACC和两个HR + ACC模型预测的PAEE与测量值高度相关(均方根误差 = 97.3 - 118.0 J·min·kg)。所有五个先前发表的模型总体上一致性良好(均方根误差 = 115.6 - 245.3 J·min·kg),但其中大多数存在系统误差,ACC的系统误差更大。

结论

ACC和HR + ACC均可用于预测儿童这六种活动期间的总体PAEE;然而,所有预测中均存在系统误差。虽然ACC和HR + ACC都能准确预测总体PAEE,但根据本研究中的活动,使用HR + ACC的PAEE预测模型可能比仅基于加速度计的模型更准确且应用更广泛。