We developed a simple and sensitive radioimmunoassay (RIA) for adenosine. The RIA is based on the double antibody method with adenosine 2', 3'-0-disuccinyl-3-[125I]-iodotyrosine methyl ester (diSc-adenosine-[125I]-TME) as a tracer. Anti-adenosine antiserum for the RIA was raised in rabbits immunized with diSc-adenosine conjugated to human serum albumin (diSc-adenosine-HSA). All samples and standards were succinylated prior to assay. The present immunoassay allows detection of 6.25-400 pmol/ml of adenosine in sample. Values obtained by the RIA and by a HPLC analysis showed a high correlation with correlation coefficient of 0.997. In order to determine adenosine in plasmas, blood cells must be separated in the presence of 6 mM EDTA, 0.006% dipyridamole (Dip) and 23 microM 2'-deoxycoformycin (dCF) at 2 degrees C. Adenosine in plasma could be accurately determined by the proposed method even without any pretreatments by deproteinizing. The adenosine levels with or without EDTA-treated normal human plasmas determined were 26.2 +/- 7.26 and 100 +/- 3.62 pmol/ml (mean +/- SEM), respectively.

摘要

我们开发了一种简单且灵敏的腺苷放射免疫分析法(RIA)。该RIA基于双抗体法,以2', 3'-O-二琥珀酰-3-[125I]-碘酪氨酸甲酯(diSc-腺苷-[125I]-TME)作为示踪剂。用于该RIA的抗腺苷抗血清是在用与人血清白蛋白偶联的diSc-腺苷(diSc-腺苷-HSA)免疫的兔中产生的。所有样品和标准品在测定前都进行了琥珀酰化处理。本免疫分析法能够检测样品中6.25 - 400 pmol/ml的腺苷。通过RIA和高效液相色谱分析获得的值显示出高度相关性,相关系数为0.997。为了测定血浆中的腺苷,必须在6 mM乙二胺四乙酸(EDTA)、0.006%双嘧达莫(Dip)和23 μM 2'-脱氧助间型霉素(dCF)存在的情况下于2℃分离血细胞。即使不进行任何去蛋白预处理,所提出的方法也能准确测定血浆中的腺苷。测定的经EDTA处理和未经处理的正常人血浆中的腺苷水平分别为26.2±7.26和100±3.62 pmol/ml(平均值±标准误)。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验