Cheng Tao, Gan Rong Z
Bioengineering Center, School of Aerospace & Mechanical Engineering, University of Oklahoma, Norman, OK 73019, USA.
J Biomech Eng. 2007 Dec;129(6):913-18. doi: 10.1115/1.2800837.
Measurement on mechanical properties of the stapedial tendon in human middle ear has not been reported in the literature. In this paper, we used the material testing system to conduct uniaxial tensile, stress relaxation, and failure tests on stapedial tendon specimens harvested from human temporal bones. The digital image correlation method was employed to assess the boundary effect on experimental data. The stress-strain relationship of the tendon obtained from experiments was analyzed using the hyperelastic Ogden model. The results presented include (1) the constitutive equation of the tendon for stretch ratio of 1-1.4 or stress range of 0-1.45 MPa, (2) the mean ultimate stress and stretch ratio of the tendon at 4.04 MPa and 1.65, respectively, and (3) the hysteresis and normalized stress relaxation function of the tendon. The data reported in this paper contribute to ear mechanics, especially for theoretical analysis of human ear function.
文献中尚未报道过对人中耳镫骨肌腱力学性能的测量。在本文中,我们使用材料测试系统对从人颞骨获取的镫骨肌腱标本进行了单轴拉伸、应力松弛和破坏试验。采用数字图像相关方法评估边界对实验数据的影响。使用超弹性奥格登模型分析从实验中获得的肌腱的应力-应变关系。给出的结果包括:(1)拉伸比为1-1.4或应力范围为0-1.45MPa时肌腱的本构方程;(2)肌腱的平均极限应力和拉伸比分别为4.04MPa和1.65;(3)肌腱的滞后现象和归一化应力松弛函数。本文报道的数据有助于耳部力学研究,特别是对人耳功能的理论分析。