Gil-Agustí Mayte, Esteve-Romero Josep, Carda-Broch Samuel
Area de Química Analítica, QFA, ESTCE, Universitat Jaume I, 12071 Castelló, Spain.
J Chromatogr A. 2008 May 2;1189(1-2):444-50. doi: 10.1016/j.chroma.2007.11.075. Epub 2007 Dec 4.
Anserine and carnosine, which are both imidazole dipeptides, are natural antioxidants that are present in some types of meat. A pure micellar liquid chromatographic procedure was developed using a micellar mobile phase of 0.10 M sodium dodecyl sulphate buffered at pH 7, an amino column and UV detection. Three types of stationary phases (C18, phenyl and amino columns) were examined and the procedure was used to determine the two compounds in meat samples. They were completely resolved without any interference from the protein band. Total analysis time was 12 min. The limits of detection (ng/mL) were 71 and 53 for anserine and carnosine, respectively. Calibration curves were constructed on three different days (r>0.998). Repeatability and intermediate precision were evaluated at three different concentrations in meat matrices, the residual standard deviations being below 2.1%. Meat samples of poultry, pork and beef were injected directly into the chromatographic system after extraction in a sodium dodecyl sulphate solution and filtration. The possibility of direct injection using micellar liquid chromatography reduces the cost and time of analyses, and decreases error sources owing to minimised risks of losses and chemical changes in the analytes. Moreover, the selection of a pure mobile phase of sodium dodecyl sulphate allows this procedure to offer a number of advantages, such as non-toxicity, non-flammability, biodegradability and low cost, in comparison with aqueous-organic solvents. Its simplicity, then, makes it a good candidate for application in routine analysis in the area of food control and quality.
鹅肌肽和肌肽均为咪唑二肽,是存在于某些肉类中的天然抗氧化剂。开发了一种纯胶束液相色谱法,使用pH值为7的0.10 M十二烷基硫酸钠胶束流动相、氨基柱和紫外检测。考察了三种固定相(C18柱、苯基柱和氨基柱),并将该方法用于测定肉类样品中的这两种化合物。它们得到了完全分离,没有受到蛋白带的任何干扰。总分析时间为12分钟。鹅肌肽和肌肽的检测限(ng/mL)分别为71和53。在三个不同日期绘制校准曲线(r>0.998)。在肉类基质中的三种不同浓度下评估了重复性和中间精密度,残留标准偏差低于2.1%。家禽、猪肉和牛肉的肉类样品在十二烷基硫酸钠溶液中萃取并过滤后直接注入色谱系统。胶束液相色谱直接进样的可能性降低了分析成本和时间,并减少了由于分析物损失和化学变化风险最小化而产生的误差来源。此外相比水-有机溶剂,选择十二烷基硫酸钠纯流动相使该方法具有许多优点,如无毒、不可燃、可生物降解和低成本。因此,其简单性使其成为食品控制和质量领域常规分析应用的良好候选方法。