采用气相色谱-正离子化学电离质谱法测定人血浆和尿液中单胺氧化酶B不可逆抑制剂(MDL 72974A)的含量。

Determination of an irreversible inhibitor of monoamine oxidase B (MDL 72974A) in human plasma and urine by gas chromatography-positive-ion chemical ionization mass spectrometry.

作者信息

Dulery B D, Schoun J, Haegele K D

机构信息

Department of Clinical Biochemistry, Marion Merrell Dow, Strasbourg, France.

出版信息

J Chromatogr. 1991 Nov 15;571(1-2):241-9. doi: 10.1016/0378-4347(91)80451-h.

Abstract

A sensitive and specific assay has been developed for the quantitative measurement in human plasma and urine of the irreversible inhibitor of monoamine oxidase B [(E)-4-fluoro-beta-fluoromethylenebenzene-butanamine HCl salt] (MDL 72974A) (I). This assay is based on gas chromatography-mass spectrometry with ammonia as the chemical ionization reagent gas. After addition of 1-fluoro-2-(4-chlorobenzene)-ethanamine HCl salt (MDL 71946A) as the internal standard, plasma (1 ml) and urine (100 microliter) samples were extracted using an automated solid-liquid extraction procedure on CN columns. The eluent was dried with a stream of nitrogen, and the residue was derivatized with pentafluoropropionic anhydride. Selected-ion monitoring of the [MNH4]+ ions m/z 361 (I) and 351 (internal standard) was used for quantification. The method yielded a linear response over the concentration range 0.25-100 pmol/ml in plasma with a limit of quantitation of 0.25 pmol/ml. The within-day reproducibility at a concentration of 5 pmol/ml was 4.6% and at a concentration of 50 pmol/ml was 1.3%. The day-to-day reproducibility was 5.2 and 7.0% at concentrations of 10 and 30 pmol/ml, respectively. The method was applied to the quantification of I in plasma and urine after the administration of 12-mg doses of I to a healthy male volunteer.

摘要

已开发出一种灵敏且特异的检测方法,用于定量测定人血浆和尿液中单胺氧化酶B的不可逆抑制剂[(E)-4-氟-β-氟亚甲基苯丁胺盐酸盐](MDL 72974A)(I)。该检测方法基于气相色谱-质谱联用,以氨作为化学电离反应气。加入1-氟-2-(4-氯苯)乙胺盐酸盐(MDL 71946A)作为内标后,采用自动固液萃取程序在CN柱上萃取血浆(1 ml)和尿液(100微升)样品。用氮气流吹干洗脱液,残渣用五氟丙酸酐进行衍生化。通过对m/z 361(I)和351(内标)的[MNH4]+离子进行选择离子监测来定量。该方法在血浆中0.25 - 100 pmol/ml的浓度范围内呈线性响应,定量限为0.25 pmol/ml。浓度为5 pmol/ml时日内重现性为4.6%,浓度为50 pmol/ml时为1.3%。浓度为10和30 pmol/ml时日间重现性分别为5.2%和7.0%。该方法应用于对一名健康男性志愿者给予12 mg剂量的I后血浆和尿液中I的定量测定。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验