Gas chromatography-negative-ion chemical ionization mass spectrometry (GC-NICI-MS) allowed the detection of extremely low plasma concentrations of 3-methoxy-4-hydroxyphenylethylene glycol (MHPG). Glucuronide and sulphate conjugates of MHPG were determined after enzymatic hydrolysis of plasma with beta-glucuronidase-arylsulphatase. A 1-ml plasma sample was extracted at the pH of the hydrolysis (pH 4.8) with ethyl acetate, and the dry extract was derivatized with pentafluoropropionic anhydride in ethyl acetate. After evaporation of the solvent, the residue was dissolved in benzene and an aliquot was analysed by GC-NICI-MS. A trideuterated analogue of MHPG was used as an internal standard. Negative-ion chemical ionization of the pentafluoropropionyl derivatives was carried out using ammonia. The ion-molecule adducts at m/e 766 and 785 (MHPG) and m/e 769 and 788 (internal standard) were formed from the pentafluoropropionyl derivatives with the ions of m/e 163 (CF3CF2COO-) and m/e 144 (loss of fluorine from m/e 163). The concentrations of the ions of m/e 163 and 144 play a major role in the sensitivity and precision of this technique, which allows the detection of free MHPG plasma concentrations as low as 100 pg/ml in routine analysis.

摘要

气相色谱 - 负离子化学电离质谱法(GC - NICI - MS)能够检测出血浆中极低浓度的3 - 甲氧基 - 4 - 羟基苯乙二醇(MHPG)。在用β - 葡萄糖醛酸酶 - 芳基硫酸酯酶对血浆进行酶水解后,测定了MHPG的葡萄糖醛酸和硫酸酯共轭物。取1 ml血浆样品,在水解pH值(pH 4.8)下用乙酸乙酯萃取,干燥提取物用乙酸乙酯中的五氟丙酸酐进行衍生化。溶剂蒸发后,残留物溶于苯中,取一份进行GC - NICI - MS分析。使用MHPG的三氘代类似物作为内标。五氟丙酰衍生物的负离子化学电离使用氨进行。在m/e 766和785(MHPG)以及m/e 769和788(内标)处的离子 - 分子加合物由五氟丙酰衍生物与m/e 163(CF3CF2COO-)和m/e 144(m/e 163失去氟)的离子形成。m/e 163和144离子的浓度在该技术的灵敏度和精密度中起主要作用,该技术在常规分析中能够检测到低至100 pg/ml的游离MHPG血浆浓度。

相似文献

7
Rapid non-enzymatic HPLC determination of total MHPG in human plasma.
Life Sci. 1990;46(4):239-46. doi: 10.1016/0024-3205(90)90029-q.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验