Helzer Laurie J, Heitkamp Kathleen M, Shein Melissa, Etzel Ruth A
Southcentral Foundation, Anchorage, Alaska 99508, USA
Int J Circumpolar Health. 2007;66 Suppl 1:29-38.
To evaluate NicAlert immunoassay test strips and liquid chromatography atmospheric-pressure ionization tandem mass spectrometry (LC/MS/MS) for the measurement of saliva cotinine levels in pregnant Alaska Native women.
Cross-sectional study.
Pregnant women completed a questionnaire about their tobacco use during pregnancy and that of others in the same household. Saliva samples were collected and tested using LC/MS/ MS and NicAlert immunoassay test strips.
Seventy-one women participated; 18 reported using tobacco products during pregnancy. Sixteen women reported smoking within the last 7 days of the interview. Median cotinine concentrations in the women who reported smoking in the last 7 days were 94.5 ng/mL using LC/MS/MS (N = 13) and 87.5 ng/mL using NicAlert (N = 11). Twenty-two women reported that they did not use tobacco and had no exposure to secondhand smoke. Median cotinine concentrations among those with no reported exposure to secondhand smoke were 0.0605 ng/mL using LC/MS/MS (N = 18) and 4.38 ng/mL using NicAlert (N = 17).
NicAlert strips can be used to quickly distinguish between users and nonusers of tobacco, but they are not adequately sensitive to detect and quantify lower concentrations of cotinine among nonsmokers with secondhand exposure. A more sensitive method such as LC/MS/MS is required for that purpose.
评估NicAlert免疫分析试纸条和液相色谱-大气压电离串联质谱法(LC/MS/MS)用于测量阿拉斯加原住民孕妇唾液中可替宁水平的情况。
横断面研究。
孕妇完成一份关于其孕期烟草使用情况以及同一家庭中其他人烟草使用情况的问卷。收集唾液样本并使用LC/MS/MS和NicAlert免疫分析试纸条进行检测。
71名女性参与研究;18名报告在孕期使用烟草制品。16名女性报告在访谈的最后7天内吸烟。在报告最后7天内吸烟的女性中,使用LC/MS/MS检测的可替宁浓度中位数为94.5纳克/毫升(N = 13),使用NicAlert检测的为87.5纳克/毫升(N = 11)。22名女性报告她们不使用烟草且未接触二手烟。在报告未接触二手烟的人群中,使用LC/MS/MS检测的可替宁浓度中位数为0.0605纳克/毫升(N = 18),使用NicAlert检测的为4.38纳克/毫升(N = 17)。
NicAlert试纸条可用于快速区分烟草使用者和非使用者,但对于检测和定量二手烟暴露的非吸烟者中较低浓度的可替宁,其灵敏度不足。为此需要一种更灵敏的方法,如LC/MS/MS。