Suppr超能文献

Effect of the use of die spacer on the marginal fit of copings cast in NiCr, NiCrBe and commercially pure titanium.

作者信息

Soriani Natércia Carreira, Leal Mônica Barbosa, Paulino Silvana Maria, Pagnano Valéria Oliveira, Bezzon Osvaldo Luiz

机构信息

Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, SP, Brazil.

出版信息

Braz Dent J. 2007;18(3):225-30. doi: 10.1590/s0103-64402007000300009.

Abstract

The goal of this study was to evaluate the effect of using die spacers on the marginal fit of NiCr (M1) and NiCrBe (M2) alloys and commercially pure titanium (cpTi) (M3) copings cast by the lost wax technique. Using a metal matrix, 45 resin added extra hard type IV stone models were obtained for the fabrication of wax patterns under the following conditions: no die spacer (A), with one die spacer layer (B) and with two die spacer layers (C), with five repetitions for each condition (alloy x die). Each die was waxed and the wax patterns were invested as per manufacturer's instructions. Three wax patterns were embedded in each casting ring, each corresponding to one of the conditions. Each coping, seated to the metal matrix by a seating pressure standardizing device (SPSD), was taken to an optical microscope for measurement of marginal discrepancy. The obtained data (microm) were analyzed statistically by ANOVA and Tukey' test (a=5%). There was statistically significant difference (p<0.05) among the materials (M1=110.67; M2=130.33 and M3=148.33). Regarding the use of the die spacer, there was a statistically significant difference (p<0.05) among the three conditions (A=162.00; B=131.06 and C=96.67). It was concluded that there is less marginal discrepancy with two die spacer layers.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验