Vavuranakis Manolis, Tzannos Konstantinos A, Thanopoulos Basil D, Vlasis Konstantinos, Stefanadis Christodoulos
1st. Department of Cardiology, University of Athens, "Hippocration" Hospital, Athens, Greece.
Hellenic J Cardiol. 2007 Nov-Dec;48(6):373-6.
Transcatheter closure of a patent ductus arteriosus (PDA) is an established technique that may rarely be complicated by severe intravascular hemolysis due to residual shunt. Although conservative management has been reported, the usual approach is to invasively eliminate the residual shunt. We report a case where misjudgment of PDA size and subsequent attempted closure with only one coil led to incomplete closure and residual shunt, which was complicated by severe intramuscular hemolysis. Effectively closing the PDA with an Amplatzer Duct Occluder resulted in immediate resolution of the hemolysis.
经导管闭合动脉导管未闭(PDA)是一种成熟的技术,但由于残余分流,很少会并发严重的血管内溶血。虽然已有保守治疗的报道,但通常的方法是通过侵入性手段消除残余分流。我们报告了一例病例,该病例中对PDA大小判断失误,随后仅用一个线圈尝试闭合,导致闭合不完全和残余分流,进而并发严重的肌内溶血。使用Amplatzer动脉导管封堵器有效闭合PDA后,溶血立即得到缓解。