Suppr超能文献

角膜塑形术隐形眼镜诱导的机械应力作用下眼表的可塑性。

Malleability of the ocular surface in response to mechanical stress induced by orthokeratology contact lenses.

作者信息

Lu Fenghe, Simpson Trefford, Sorbara Luigina, Fonn Desmond

机构信息

Centre for Contact Lens Research, School of Optometry, University of Waterloo, Waterloo, Ontario, Canada.

出版信息

Cornea. 2008 Feb;27(2):133-41. doi: 10.1097/ICO.0b013e318158b4b5.

Abstract

PURPOSE

To determine the malleability of the ocular surface by examining the acute effects of local mechanical stress on optical performance, corneal shape, and corneal/epithelial thickness after corneal refractive therapy for myopia and hyperopia (CRT and CRTH).

METHODS

Twenty ametropes (spherical equivalent: -2.08 +/- 2.31 D) wore CRT and CRTH lenses in a random order on 1 eye (randomly selected). The lenses were worn for 15, 30, and 60 minutes (randomly ordered, with each period taking place on a different day). Refractive error, aberrations, corneal topography, and corneal/epithelial thickness (using OCT) were measured before and after lens wear. The measurements were performed on the control eyes at the 60-minute visit only.

RESULTS

With both CRT and CRTH lens wear, significant changes occurred in many parameters from the 15-minute time point. The refractive error and defocus decreased after CRT lens wear (all P < 0.05) and increased after CRTH lens wear from baseline (all P < 0.05). Astigmatism did not change (both P > 0.05). Higher-order aberrations, including coma and spherical aberration (SA), increased after CRT and CRTH lens wear (all P < 0.05) from baseline, but the signed SA shifted from positive to negative after CRTH lens wear (P < 0.05). The central cornea flattened and the midperiphery steepened after CRT lens wear, whereas the central cornea steepened and paracentral region flattened after CRTH lens wear (P < 0.05). The central cornea swelled less than the midperiphery after CRT lens wear (P < 0.05), whereas the central cornea swelled more than the paracentral region after CRTH lens wear (P < 0.05). The central epithelium was thinner than the midperiphery after CRT lens wear (P < 0.05) and thicker than the paracentral region after CRTH lens wear (P < 0.05). Optical performance, corneal curvature, and epithelial thickness did not change from baseline in the control eyes (all P > 0.05).

CONCLUSIONS

CRT lenses for myopia and hyperopia induce significant structural and optical changes in as little as 15 minutes. The cornea, particularly the epithelium, is remarkably malleable, with rapid steepening and flattening possible in little time.

摘要

目的

通过检查近视和远视角膜屈光治疗(CRT和CRTH)后局部机械应力对光学性能、角膜形状以及角膜/上皮厚度的急性影响,来确定眼表的可塑性。

方法

20名屈光不正患者(球镜等效度:-2.08±2.31D)在一只随机选择的眼睛上随机佩戴CRT和CRTH镜片。镜片佩戴15、30和60分钟(随机排序,每个时间段在不同日期进行)。在佩戴镜片前后测量屈光不正、像差、角膜地形图以及角膜/上皮厚度(使用光学相干断层扫描)。仅在60分钟就诊时对对照眼进行测量。

结果

佩戴CRT和CRTH镜片后,从15分钟时间点起许多参数都发生了显著变化。佩戴CRT镜片后屈光不正和散焦减小(所有P<0.05),佩戴CRTH镜片后相对于基线增加(所有P<0.05)。散光未改变(两者P>0.05)。包括彗差和球差(SA)在内的高阶像差在佩戴CRT和CRTH镜片后相对于基线增加(所有P<0.05),但佩戴CRTH镜片后有符号的SA从正值变为负值(P<0.05)。佩戴CRT镜片后中央角膜变平,中周边角膜变陡,而佩戴CRTH镜片后中央角膜变陡,旁中央区域变平(P<0.05)。佩戴CRT镜片后中央角膜肿胀程度小于中周边角膜(P<0.05),而佩戴CRTH镜片后中央角膜肿胀程度大于旁中央区域(P<0.05)。佩戴CRT镜片后中央上皮比中周边薄(P<0.05),佩戴CRTH镜片后比旁中央区域厚(P<0.05)。对照眼的光学性能、角膜曲率和上皮厚度相对于基线未改变(所有P>0.05)。

结论

用于近视和远视的CRT镜片在短短15分钟内就能引起显著的结构和光学变化。角膜,尤其是上皮,具有显著的可塑性,能在短时间内迅速变陡和平坦。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验