da Silva F C S, Halloran S T, Kos A B, Pappas D P
University of Colorado Denver, Denver, Colorado, 80217-3364, USA.
Rev Sci Instrum. 2008 Jan;79(1):013709. doi: 10.1063/1.2829883.
We present the design and fabrication of a magnetoresistive imaging system capable of scanning 256 channels simultaneously along linear ranges of either 4 or 13 mm. High speed electronics read the channels and transfer the data to a computer that builds and displays the images. The system was successfully used to image magnetic tapes for real-time forensic validation purposes and can also be applied in other noninvasive imaging applications.
我们展示了一种磁阻成像系统的设计与制造,该系统能够沿4毫米或13毫米的线性范围同时扫描256个通道。高速电子设备读取这些通道并将数据传输到一台构建并显示图像的计算机。该系统已成功用于对磁带进行成像以用于实时法医验证目的,并且还可应用于其他非侵入性成像应用。