Suppr超能文献

Abdominal aortic aneurysm surgery with mechanical support using the Impella microaxial blood pump.

作者信息

Farhat Fadi, Sassard Thomas, Attof Yassin, Jegaden Olivier

机构信息

Department of Cardiovascular Surgery B, Hôpital Cardiovasculaire et Pneumologique Louis Pradel, Université Claude Bernard, Inserm U886, 28, avenue du doyen Lépine, 69677, Bron Cedex, France.

出版信息

Interact Cardiovasc Thorac Surg. 2008 May;7(3):524-5. doi: 10.1510/icvts.2007.173146. Epub 2008 Feb 14.

Abstract

A 50-year-old man with an end-stage cardiac failure was referred to our institution for pre-transplantation assessment. An infrarenal aortic aneurysm (diameter 45 mm) was discovered and progressed (up to 59 mm) over a two-month period. Decision to perform aneurysmectomy with the support of an Impella Recover LP50 microaxial blood pump was decided regarding the rapid evolution of the disease. The patient had uneventful cardiac-wise during surgery and postoperative period.