Chen Yi-Te, Chen Wei-Ming, Lee Kung-Sheng, Huang Ching-Kuei, Chiang Chao-Ching, Chen Tain-Hsiung
Department of Orthopedics and Traumatology, Shin Kong Wu Ho-Su Memorial Hospital, and Department of Surgery, National Yang-Ming University, Taipei, Taiwan.
J Arthroplasty. 2008 Feb;23(2):241-6. doi: 10.1016/j.arth.2007.03.042. Epub 2007 Nov 7.
Between 1997 and 2004, 18 patients (8 men and 10 women, with a mean age of 73.2 years) with failed treatment of intertrochanteric hip fractures underwent hip arthroplasty as salvage procedures at our institution. Cementless, 5/8-porous coated, 6-in. primary diaphyseal locking femoral stems were used. Prospective follow-up ranging from 2 to 5 years (mean, 37.1 months) showed improvement of hip function without prosthesis loosening. Complications included 1 case of postoperative infection, 2 cases of dislocation, and 2 cases of stem subsidence. The clinical results were satisfactory. The 5/8-porous coated, 6-in. cementless femoral stems could be used in the salvage procedures for failed fixation of intertrochanteric hip fractures.