Abstract

BACKGROUND AND OBJECTIVES

Oxygen permeability is important in platelet storage media. We compared a new polyolefin container with enhanced oxygen permeability (PO-80; Kawasumi, Tokyo, Japan) to a widely used alternative (PL2410; Baxter Healthcare, Deerfield, IL, USA).

MATERIALS AND METHODS

In vitro characteristics of paired platelet concentrates (PCs; mean 4.2 x 10(11)/250 ml plasma/bag) stored in PO-80 or PL2410 were assessed through 9 days of storage. In vivo recovery and survival of 7-day-old autologous PCs were assessed according to the Murphy method.

RESULTS

Laboratory assessment of platelet quality favoured PO-80 during 9 days of storage with statistically significant differences in glucose consumption (2.75 vs. 4.93 mmol/10(12)/24 h in the interval 120-168 h), lactate generation (4.37 vs. 8.11 mmol/10(12)/24 h in the interval 120-168 h), pressure of oxygen (pO(2)) (59.3 vs. 38.1 mmHg at day 1), and HCO(3)(-) (14.7 vs. 13.4 mmol/l at day 1). Statistically significant differences were not seen in aggregation, hypotonic shock response or pH. In vivo assessment of autologous platelets stored 7 days in the PO-80 container revealed that recovery was 82.1% and survival was 81.0% of fresh control. Seven-day stored PCs in PO-80 were shown in vivo to be non-inferior to fresh platelets, with upper confidence limits (UCL(95)) in recovery and survival of stored PCs below the maximum acceptable difference (MAD); 15.3% UCL(95) < 20.4% MAD and 2.1 days UCL(95) < 2.1 days MAD.

CONCLUSIONS

The in vitro characteristics of PCs stored in a highly oxygen-permeable container were stable at least 7 days. The in vivo study supports the suitability of PO-80 for 7-day platelet storage.

摘要

背景与目的

氧透过率在血小板储存介质中很重要。我们将一种具有增强氧透过性的新型聚烯烃容器(PO - 80;日本东京川澄)与一种广泛使用的替代容器(PL2410;美国伊利诺伊州迪尔菲尔德的百特医疗保健公司)进行了比较。

材料与方法

对储存在PO - 80或PL2410中的配对血小板浓缩物(PCs;平均4.2×10¹¹/250 ml血浆/袋)进行9天储存期的体外特性评估。根据墨菲法评估7日龄自体PCs的体内回收率和存活率。

结果

在9天的储存期内,对血小板质量的实验室评估显示PO - 80更具优势,在葡萄糖消耗(120 - 168小时期间为2.75 vs. 4.93 mmol/10¹²/24小时)、乳酸生成(120 - 168小时期间为4.37 vs. 8.11 mmol/10¹²/24小时)、氧分压(pO₂)(第1天为59.3 vs. 38.1 mmHg)和碳酸氢根(HCO₃⁻)(第1天为14.7 vs. 13.4 mmol/l)方面存在统计学显著差异。在聚集、低渗休克反应或pH值方面未观察到统计学显著差异。对在PO - 80容器中储存7天的自体血小板进行的体内评估显示,回收率为新鲜对照的82.1%,存活率为81.0%。在体内,储存在PO - 80中的7日龄PCs显示不劣于新鲜血小板,储存PCs的回收率和存活率的95%置信上限(UCL(95))低于最大可接受差异(MAD);回收率UCL(95) 15.3% < 20.4% MAD,存活率UCL(95) 2.1天 < 2.1天MAD。

结论

储存在高氧透过性容器中的PCs的体外特性至少7天保持稳定。体内研究支持PO - 80适用于7天的血小板储存。