Multi-rule quality control for the age-related eye disease study.

作者信息

Caudill Samuel P, Schleicher Rosemary L, Pirkle James L

机构信息

Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control & Prevention, Public Health Service, U.S. Department of Health and Human Services, Atlanta, GA 30333, USA.

出版信息

Stat Med. 2008 Sep 10;27(20):4094-106. doi: 10.1002/sim.3222.

Abstract

The Age-Related Eye Disease Study (AREDS), sponsored by the National Eye Institute, was designed to study the natural history and risk factors of age-related macular degeneration (AMD) and cataract, and to evaluate the effect of high doses of antioxidants and zinc on eye disease progression. AMD and cataract are leading causes of visual impairment and blindness in the U.S., with frequency of both diseases increasing dramatically after age 65. Participants were randomly chosen to receive antioxidant or placebo tablets. Blood was drawn annually from a subset of patients, and serum concentrations of 17 different nutritional indicators were measured. Because of the complexity of the analytical methods, and possibility of instrument error due to failure of any one of many component parts, several different instruments were used for most analytes. In addition, to assure that the measurement systems were performing adequately across a wide range of concentrations, multiple control pools were monitored with analyte concentrations at low, medium, and high concentrations. We report here the multi-rule quality control system (MRQCS) used during the later part of the trial (AREDS Phase III). This system was designed to monitor systematic error and random within- and among-run error for analytical runs using 1-3 different quality control pools per run and 1-2 measurements of each pool per run. We demonstrate the features of the MRQCS using quality control (QC) data associated with vitamin C measurements. We also provide operating characteristics to demonstrate how the MRQCS responds to increases in systematic and/or random error.

摘要

由美国国立眼科研究所资助的年龄相关性眼病研究(AREDS)旨在研究年龄相关性黄斑变性(AMD)和白内障的自然病史及危险因素,并评估高剂量抗氧化剂和锌对眼病进展的影响。在美国,AMD和白内障是导致视力损害和失明的主要原因,这两种疾病的发病率在65岁之后都急剧上升。参与者被随机选择接受抗氧化剂或安慰剂片剂。每年从一部分患者中采集血液,并测量17种不同营养指标的血清浓度。由于分析方法的复杂性以及众多组成部件中任何一个出现故障可能导致仪器误差,大多数分析物使用了几种不同的仪器。此外,为确保测量系统在广泛的浓度范围内都能正常运行,监测了多个对照样本池,其分析物浓度分别处于低、中、高浓度水平。我们在此报告试验后期(AREDS第三阶段)使用的多规则质量控制系统(MRQCS)。该系统旨在监测分析运行中的系统误差以及批内和批间随机误差,每次运行使用1 - 3个不同的质量控制样本池,每个样本池每次运行测量1 - 2次。我们使用与维生素C测量相关的质量控制(QC)数据展示了MRQCS的特点。我们还提供了操作特性,以说明MRQCS如何应对系统误差和/或随机误差的增加。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验