Suppr超能文献

有明显视力损害的青光眼患者半自动与手动Goldmann动态视野检查的比较

A comparison of semiautomated versus manual Goldmann kinetic perimetry in patients with visually significant glaucoma.

作者信息

Ramirez Adriana M, Chaya Craig J, Gordon Lynn K, Giaconi Joann A

机构信息

David Geffen School of Medicine at UCLA, Los Angeles, CA 90095, USA.

出版信息

J Glaucoma. 2008 Mar;17(2):111-7. doi: 10.1097/IJG.0b013e31814b9985.

Abstract

PURPOSE

To determine if semiautomated kinetic perimetry (SKP) is reproducible and comparable to Goldmann manual kinetic perimetry (GVF).

METHODS

Glaucoma patients were recruited to perform visual field testing using GVF and SKP. Specific isopters were tested, quantified, and compared. Visual field patterns were analyzed for shape and defect.

RESULTS

Ten patients (16 eyes) underwent visual field studies using SKP and GVF, and 8 patients completed a second SKP on a different day. Individual isopter areas were similar between GVF and SKP, although 60% of isopters were larger on SKP by an average of 15%. This was statistically significant for the smaller isopters, I4e (P=0.02) and I2e (P=0.05). Retesting with SKP on a separate day, showed similar isopter areas (P values=0.3 to 1.0), however, the exact location of isopters in degrees from central fixation tended to vary with the smaller test object sizes. Isopter position in degrees from the central axis agreed in at least 3 quadrants in approximately 65% of fields compared. SKP visual field defects and patterns were similar between test strategies.

CONCLUSIONS

SKP and GVF testing produce similar visual field results in glaucoma patients, and SKP testing seems to be reliable and reproducible in this population. However, overlapping isopters, typically associated with nonorganic vision loss, and jagged isopters were sometimes observed in SKP visual fields. Further study of SKP is needed to explore these findings.

摘要

目的

确定半自动动态视野计(SKP)是否具有可重复性,以及是否与戈德曼手动动态视野计(GVF)相当。

方法

招募青光眼患者使用GVF和SKP进行视野测试。对特定的等视线进行测试、量化并比较。分析视野模式的形状和缺损情况。

结果

10名患者(16只眼)使用SKP和GVF进行了视野研究,8名患者在不同日期完成了第二次SKP检查。GVF和SKP的个体等视线面积相似,不过60%的等视线在SKP上更大,平均增大15%。对于较小的等视线I4e(P = 0.02)和I2e(P = 0.05),这具有统计学意义。在另一天用SKP重新测试,显示等视线面积相似(P值 = 0.3至1.0),然而,等视线相对于中央注视点的精确位置往往会随着较小测试物体尺寸而变化。在大约65%的被比较视野中,等视线相对于中央轴的位置在至少3个象限中是一致的。不同测试策略下SKP的视野缺损和模式相似。

结论

SKP和GVF测试在青光眼患者中产生相似的视野结果,并且SKP测试在该人群中似乎可靠且可重复。然而,在SKP视野中有时会观察到通常与非器质性视力丧失相关的重叠等视线和锯齿状等视线。需要对SKP进行进一步研究以探讨这些发现。