Suppr超能文献

3-T磁共振成像下用于胶质瘤分级的扩散张量成像:分数各向异性和平均扩散率分析

Diffusion-tensor imaging for glioma grading at 3-T magnetic resonance imaging: analysis of fractional anisotropy and mean diffusivity.

作者信息

Lee Ho Yun, Na Dong Gyu, Song In-Chan, Lee Dong Hoon, Seo Hyung Suk, Kim Ji-hoon, Chang Kee-Hyun

机构信息

Department of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, Clinical Research Institute, Seoul National University Hospital, Seoul, Korea.

出版信息

J Comput Assist Tomogr. 2008 Mar-Apr;32(2):298-303. doi: 10.1097/RCT.0b013e318076b44d.

Abstract

PURPOSE

To retrospectively determine whether fractional anisotropy (FA) or mean diffusivity (MD) value at 3-T diffusion-tensor imaging is different between low- and high-grade gliomas and may be useful for glioma grading.

METHODS

Review board approval was obtained, and informed consent was waived. Diffusion-tensor imaging was performed in 27 patients with surgically proved gliomas (19 high-grade and 8 low-grade gliomas). Fractional anisotropy and MD values were measured in 3 regions; peritumoral edema, and enhancing and nonenhancing tumor regions. We compared mean FA and MD values of nonenhancing tumor regions between low- and high-grade gliomas and compared the FA and MD values among the 3 mentioned regions in high-grade gliomas. The relationship between FA and MD values of tumors was also investigated. Statistical analysis was performed using the Student t test and Pearson correlation coefficients.

RESULTS

In the nonenhancing regions of tumors, FA ratios were not significantly different between low- and high-grade gliomas (0.472 and 0.701, P = 0.075), but MD ratios were significantly lower in high-grade gliomas (1.899 and 1.23, P < 0.001). In high-grade gliomas, enhancing tumors showed a tendency toward a lower FA ratio than nonenhancing tumors (P = 0.034), but FA values or ratios of peritumoral edema were not significantly different from those of enhancing or nonenhancing tumor. No strong relationship was found between FA and MD values.

CONCLUSIONS

Fractional anisotropy values of low- and high-grade gliomas were not significantly different. However, MD values of nonenhancing low-grade gliomas were significantly higher than those of nonenhancing high-grade gliomas, which will be useful for the grading of nonenhancing infiltrative gliomas.

摘要

目的

回顾性确定3-T扩散张量成像时低级和高级别胶质瘤之间的分数各向异性(FA)或平均扩散率(MD)值是否存在差异,以及其是否有助于胶质瘤分级。

方法

获得了审查委员会的批准,并免除了知情同意。对27例经手术证实为胶质瘤的患者(19例高级别胶质瘤和8例低级别胶质瘤)进行了扩散张量成像。在3个区域测量FA值和MD值,即瘤周水肿区、强化肿瘤区和非强化肿瘤区。我们比较了低级和高级别胶质瘤非强化肿瘤区的平均FA值和MD值,并比较了高级别胶质瘤上述3个区域的FA值和MD值。还研究了肿瘤的FA值和MD值之间的关系。使用Student t检验和Pearson相关系数进行统计分析。

结果

在肿瘤的非强化区域,低级和高级别胶质瘤之间的FA比率无显著差异(分别为0.472和0.701,P = 0.075),但高级别胶质瘤的MD比率显著更低(分别为1.899和1.23,P < 0.001)。在高级别胶质瘤中,强化肿瘤的FA比率有低于非强化肿瘤的趋势(P = 0.034),但瘤周水肿的FA值或比率与强化或非强化肿瘤的FA值或比率无显著差异。未发现FA值和MD值之间有强相关性。

结论

低级和高级别胶质瘤的分数各向异性值无显著差异。然而,非强化低级胶质瘤的MD值显著高于非强化高级别胶质瘤,这将有助于非强化浸润性胶质瘤的分级。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验