To investigate the validity of the Jessen formula, with a compression factor of 0.75, in determining the back optic zone radius (BOZR) of an orthokeratology (ortho-k) lens for myopic reduction [i.e. BOZR = flattest K- (target reduction + 0.75)].
One hundred and twenty-three consecutive ortho-k patient files from the Optometry Clinic of The Hong Kong Polytechnic University were reviewed. Pertinent data at the preliminary visit and at the morning visit after 2 weeks of lens wear for 63 patients who fulfilled the inclusion criteria were retrieved for analysis. All patients were either fitted with DreimLens (DreimLens Taiwan, Taiwan Macro Vision Group, Taiwan, China) or eLens (E&E Optics Ltd., Hong Kong SAR, China) designs. Only data from the right eye were analysed. The validity of the Jessen formula was evaluated by comparing the equation of the plot of myopic reduction attempted (based on the Jessen formula) and myopic reduction achieved (based on subjective refraction).
The Jessen formula was found to underestimate the intended target of myopic reduction following ortho-k. The results suggested that the formula should be revised to BOZR = flattest K- (1.23 target reduction + 1.27).
If the intention is to overcorrect the ortho-k patient by 0.75 D to allow for regression during the daytime, the Jessen formula with a compression factor of 0.75 is not valid to determine the BOZR of the ortho-k lens designs.
研究压缩因子为0.75的耶森公式在确定用于近视控制的角膜塑形镜的后光学区半径(BOZR)时的有效性[即BOZR = 最平坦角膜曲率 - (目标降低度数 + 0.75)]。
回顾了香港理工大学验光诊所123例连续的角膜塑形镜患者档案。检索了63例符合纳入标准的患者在初次就诊时以及戴镜2周后的早晨就诊时的相关数据进行分析。所有患者均佩戴DreimLens(中国台湾宏景集团台湾德瑞视光学)或eLens(中国香港特别行政区E&E光学有限公司)设计的镜片。仅分析右眼数据。通过比较尝试的近视降低度数(基于耶森公式)和实际实现的近视降低度数(基于主观验光)绘制的曲线方程来评估耶森公式的有效性。
发现耶森公式低估了角膜塑形镜术后预期的近视降低目标。结果表明该公式应修订为BOZR = 最平坦角膜曲率 - (1.23×目标降低度数 + 1.27)。
如果打算对角膜塑形镜患者过度矫正0.75 D以适应白天的度数回退,则压缩因子为0.75的耶森公式在确定角膜塑形镜设计的BOZR时无效。