To report an initial clinical urologic experience with a new laparoscopic access port (R-Port) and the advent of the single-port access (SPA) procedure and one-port umbilical surgery (OPUS).
Five patients underwent therapeutic laparoscopic interventions (two simple nephrectomies for end-stage kidney disease consequent to stone disease, one orchidopexy, one orchidectomy, and one ureterolithotomy), with one R-Port used for each. Three of these procedures were OPUS, and the other two were SPA procedures. In all cases a 5-mm 30 degrees telescope and two 5-mm working instruments were inserted through the port. In the case of the nephrectomies, hemostasis and pedicle control was obtained with the Harmonic Scalpel and Hem-o-lok clips; a novel multi-instrument port cap allowed for safe introduction of a 10-mm clip applier. Frequent instrument changes effected as necessary to allow the operative procedure to proceed to completion did not affect the seal.
All procedures were completed uneventfully. Operative time averaged 83 minutes. There were no perioperative port-related or surgical complications in these cases.
The R-Port allows laparoscopic surgery to be performed safely with fewer ports, thereby allowing for SPA and OPUS with their inherent cosmetic advantages and reduction in postoperative discomfort. More studies are being carried out.
报告使用新型腹腔镜接入端口(R-Port)的初步临床泌尿外科经验,以及单孔接入(SPA)手术和单孔脐部手术(OPUS)的出现。
5例患者接受了腹腔镜治疗性干预(2例因结石病导致终末期肾病行单纯肾切除术、1例睾丸固定术、1例睾丸切除术和1例输尿管切开取石术),每例均使用1个R-Port。其中3例手术为OPUS,另外2例为SPA手术。所有病例均通过该端口插入1个5毫米30度的腹腔镜和2个5毫米的操作器械。在肾切除术中,使用超声刀和Hem-o-lok夹进行止血和控制肾蒂;一种新型的多器械端口帽允许安全引入10毫米的夹钳。根据需要频繁更换器械以完成手术操作,这并未影响密封效果。
所有手术均顺利完成。平均手术时间为83分钟。这些病例中无围手术期与端口相关的并发症或手术并发症。
R-Port可减少端口数量安全地进行腹腔镜手术,从而实现具有固有美容优势且能减轻术后不适的SPA和OPUS。更多研究正在进行中。