Suppr超能文献

对比增强三维多巴酚丁胺负荷超声心动图:在锡拉岩礁和卡律布狄斯大漩涡之间?

Contrast-enhanced three-dimensional dobutamine stress echocardiography: between Scylla and Charybdis?

作者信息

Krenning Boudewijn J, Nemes Attila, Soliman Osama I I, Vletter Wim B, Voormolen Marco M, Bosch Johan G, Ten Cate Folkert J, Roelandt Jos R T C, Geleijnse Marcel L

机构信息

Department of Cardiology, Erasmus MC, Thoraxcenter, Room Ba 316, Dr Molewaterplein 40, 3015 GD Rotterdam, The Netherlands.

出版信息

Eur J Echocardiogr. 2008 Nov;9(6):757-60. doi: 10.1093/ejechocard/jen136. Epub 2008 Apr 14.

Abstract

AIMS

Real-time three-dimensional echocardiography (RT3DE) allows quick volumetric scanning of the left ventricle (LV). We evaluated the diagnostic accuracy of contrast-enhanced stress RT3DE for the detection of coronary artery disease (CAD) in comparison with coronary arteriography as the reference technique.

METHODS AND RESULTS

Forty-five consecutive patients (age 59 +/- 10, 31 males) referred for coronary angiography were examined by contrast-enhanced RT3DE. Wall motion analysis was performed off-line by dedicated software. New or worsening wall motion abnormalities were detected in 17 of 28 patients with significant CAD (sensitivity 61%), and in two of 17 patients without significant CAD (specificity 88%). The sensitivity for detection of single-vessel CAD was 8/15 patients (53%), for two-vessel CAD 4/6 (67%), and for three-vessel CAD 5/7 (71%). In 35 patients, comparison with conventional RT3DE was available. The image quality index at rest improved from 2.5 +/- 1.2 to 3.2 +/- 1.0 (P < 0.001) with contrast and at peak stress from 2.3 +/- 1.2 to 3.1 +/- 1.0 (P < 0.001). Interobserver agreement on the diagnosis of myocardial ischaemia improved from 26 of 35 studies (74%, kappa = 0.44) with conventional stress RT3DE to 30 of 35 studies (86%, kappa = 0.69) with contrast-enhanced stress RT3DE. Sensitivity increased from 50 to 55% and specificity from 69 to 85% with contrast-enhanced stress RT3DE in this subset of patients.

CONCLUSION

Despite some important practical and theoretical benefits, contrast-enhanced stress RT3DE currently has only moderate diagnostic sensitivity due to several technical limitations as temporal and spatial resolution.

摘要

目的

实时三维超声心动图(RT3DE)能够快速对左心室(LV)进行容积扫描。我们以冠状动脉造影作为参考技术,评估了对比增强负荷RT3DE检测冠状动脉疾病(CAD)的诊断准确性。

方法与结果

连续45例因冠状动脉造影前来就诊的患者(年龄59±10岁,男性31例)接受了对比增强RT3DE检查。通过专用软件进行离线壁运动分析。在28例有显著CAD的患者中,17例检测到新的或加重的壁运动异常(敏感性61%),在17例无显著CAD的患者中,2例检测到异常(特异性88%)。检测单支血管CAD的敏感性为8/15例患者(53%),两支血管CAD为4/6例(67%),三支血管CAD为5/7例(71%)。35例患者可与传统RT3DE进行比较。静息时的图像质量指数对比剂增强后从2.5±1.2提高到3.2±1.0(P<0.001),负荷峰值时从2.3±1.2提高到3.1±1.0(P<0.001)。观察者间对心肌缺血诊断的一致性从传统负荷RT3DE时35项研究中的26项(74%,kappa=0.44)提高到对比增强负荷RT3DE时35项研究中的30项(86%,kappa=0.69)。在这组患者中,对比增强负荷RT3DE时敏感性从50%提高到55%,特异性从69%提高到85%。

结论

尽管对比增强负荷RT3DE有一些重要的实际和理论优势,但由于时间和空间分辨率等若干技术限制,目前其诊断敏感性仅为中等。