Owen S L F, Heath J, Kringelbach M, Green A L, Pereira E A C, Jenkinson N, Jegan T, Stein J F, Aziz T Z
Oxford Functional Neurosurgery, John Radcliffe Hospital, Headington, Oxford OX3 9DU, UK.
J Clin Neurosci. 2008 Jul;15(7):801-5. doi: 10.1016/j.jocn.2007.06.010. Epub 2008 May 20.
This study aimed to examine, using diffusion tensor imaging (DTI), differences in electrode placement in four patients undergoing deep brain stimulation for chronic neuropathic pain of varying aetiology. A pre-operative DTI was obtained for each patient, who was then implanted with deep brain stimulation electrodes in the periventricular/periaqueductal grey area with good pain relief. Using seeds from the postoperative MRI scan, probabilistic tractography was performed from the pre-operative DTI.
本研究旨在利用扩散张量成像(DTI)检查4例因不同病因的慢性神经性疼痛而接受脑深部电刺激治疗的患者在电极放置上的差异。为每位患者术前获取DTI,然后在脑室周围/导水管周围灰质区域植入脑深部电刺激电极,患者疼痛得到有效缓解。利用术后MRI扫描的种子点,根据术前DTI进行概率性纤维束成像。