Suppr超能文献

纵向和扭转式超声乳化的累计刀头行程及隐含的跟随性

Cumulative tip travel and implied followability of longitudinal and torsional phacoemulsification.

作者信息

Davison James A

机构信息

Department of Ophthalmology and Visual Science, University of Utah, Salt Lake City, Utah, USA.

出版信息

J Cataract Refract Surg. 2008 Jun;34(6):986-90. doi: 10.1016/j.jcrs.2008.02.029.

Abstract

PURPOSE

To compare surgeon-generated tip travel and surgical time of longitudinal and torsional phacoemulsification with straight and angled tips.

SETTING

Private practice, Marshalltown, Iowa, USA.

METHOD

The study analyzed surgical videos of 46 phacoemulsification cases performed by 1 surgeon. Based on the tip and type of ultrasound (US) used, the cases were prospectively assigned to 1 of 4 groups and operated on consecutively: straight tip/longitudinal US, straight tip/torsional US, angled tip/longitudinal US, and angled tip/torsional US. Digital Video Measurement System software (Caltex Scientific) was used to measure the phacoemulsification tip's travel during the removal of all 4 nuclear quadrants and the removal of quadrants 2 and 3 (2+3) and to determine surgical time. The cumulative travel distance and surgical time of the 4 groups were compared using analysis of variance.

RESULTS

The angled tip/torsional US combination reduced tip travel by more than 40% compared with the straight tip/longitudinal US when comparing travel to aspirate all 4 quadrants and quadrants 2+3. Surgical time in the removal of all 4 quadrants and quadrants 2+3 was significantly lower in the angled tip/torsional US group than in the other groups.

CONCLUSIONS

Torsional phacoemulsification using an angled tip required less surgeon-generated tip travel and less time, suggesting that nuclear material may be more efficiently approximated to and aspirated through the tip aperture throughout the phacoemulsification process. Shorter cumulative tip travel and less procedure time imply increased nuclear followability, fewer reacquisition movements, and increased phacoemulsification efficiency and safety.

摘要

目的

比较使用直头和弯头的纵向及扭转式超声乳化手术中术者操作的探头移动距离和手术时间。

地点

美国爱荷华州马歇尔敦的私人诊所。

方法

本研究分析了由1名外科医生进行的46例超声乳化手术的视频。根据所使用的探头及超声类型,这些病例被前瞻性地分为4组中的1组并连续进行手术:直头/纵向超声、直头/扭转式超声、弯头/纵向超声、弯头/扭转式超声。使用数字视频测量系统软件(Caltex Scientific)测量在摘除所有4个核象限以及摘除第2和第3象限(2 + 3)过程中超声乳化探头的移动距离,并确定手术时间。使用方差分析比较4组的累积移动距离和手术时间。

结果

在比较吸取所有4个象限以及2 + 3象限的移动距离时,弯头/扭转式超声组合与直头/纵向超声相比,探头移动距离减少了40%以上。在摘除所有4个象限以及2 + 3象限的过程中,弯头/扭转式超声组的手术时间显著低于其他组。

结论

使用弯头的扭转式超声乳化术所需的术者操作探头移动距离更短,时间更少,这表明在整个超声乳化过程中,核物质可能能更有效地靠近并通过探头开口被吸出。累积探头移动距离更短以及手术时间更少意味着核物质跟随性增强、重新获取动作减少,以及超声乳化效率和安全性提高。

相似文献

1
Cumulative tip travel and implied followability of longitudinal and torsional phacoemulsification.
J Cataract Refract Surg. 2008 Jun;34(6):986-90. doi: 10.1016/j.jcrs.2008.02.029.
2
Outcomes of torsional microcoaxial phacoemulsification using tips with 30-degree and 45-degree aperture angles.
J Cataract Refract Surg. 2014 Mar;40(3):362-8. doi: 10.1016/j.jcrs.2013.07.051. Epub 2014 Jan 17.
4
Bead-flow pattern: quantitation of fluid movement during torsional and longitudinal phacoemulsification.
J Cataract Refract Surg. 2010 Jun;36(6):1018-23. doi: 10.1016/j.jcrs.2009.12.028.
5
Ultra-high-speed digital video images of vibrations of an ultrasonic tip and phacoemulsification.
J Cataract Refract Surg. 2008 Jun;34(6):1024-8. doi: 10.1016/j.jcrs.2008.02.020.
6
Comparison of torsional and longitudinal modes using phacoemulsification parameters.
J Cataract Refract Surg. 2009 Oct;35(10):1719-24. doi: 10.1016/j.jcrs.2009.04.047.
7
Phacoemulsification efficiency with a radiused phaco tip.
J Cataract Refract Surg. 2014 May;40(5):818-21. doi: 10.1016/j.jcrs.2013.11.029.
8
Comparison of two different ultrasound methods of phacoemulsification.
Am J Ophthalmol. 2014 Aug;158(2):221-226.e1. doi: 10.1016/j.ajo.2014.04.015. Epub 2014 Apr 30.
10
Outcomes of torsional microcoaxial phacoemulsification performed by 12-degree and 22-degree bent tips.
J Cataract Refract Surg. 2013 Aug;39(8):1219-25. doi: 10.1016/j.jcrs.2013.03.002. Epub 2013 May 23.

引用本文的文献

5
A novel method to compare phacoemulsification parameters in vivo: two halves of one nucleus.
Graefes Arch Clin Exp Ophthalmol. 2016 Aug;254(8):1579-1584. doi: 10.1007/s00417-016-3376-0. Epub 2016 Jun 21.
6
Comparison of 45-degree Kelman and 45-degree balanced phaco tip designs in torsional microcoaxial phacoemulsification.
Int J Ophthalmol. 2015 Dec 18;8(6):1168-72. doi: 10.3980/j.issn.2222-3959.2015.06.16. eCollection 2015.
8
Results of endocapsular phacofracture debulking of hard cataracts.
Clin Ophthalmol. 2015 Jul 10;9:1233-8. doi: 10.2147/OPTH.S85939. eCollection 2015.
9
Effect of torsional mode phacoemulsification on cornea in eyes with/without pseudoexfoliation.
Int J Ophthalmol. 2015 Apr 18;8(2):281-7. doi: 10.3980/j.issn.2222-3959.2015.02.12. eCollection 2015.
10
Ozil® versus conventional ultrasound phacoemulsification: a randomized comparative study.
Int Ophthalmol. 2015 Aug;35(4):565-8. doi: 10.1007/s10792-014-9984-y. Epub 2014 Aug 26.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验