Luo Cheng, Long Jiangang, Liu Jiankang
Institute for Nutritional Science, Shanghai Institutes of Biological Sciences, Chinese Academy of Sciences, Shanghai 200031, China.
Clin Chim Acta. 2008 Sep;395(1-2):38-41. doi: 10.1016/j.cca.2008.04.025. Epub 2008 May 7.
The determination of the activity of complex III in tissue samples provides critical evidence in the diagnosis of mitochondrial disorders and diseases associated with mitochondrial dysfunction. However, great variations have been seen in the literature due to the use of different assays.
Reaction conditions of an improved spectrophotometric method exhibiting higher specificity for complex III activity than the methods currently used, were studied.
Optimum conditions, using bovine serum albumin at 0.01% and Tween-20 at 0.05%, were defined. The present method possesses more antimycin A-sensitive complex III activity, compared to previous methods. Thus, this improved method is sensitive and suitable for assaying complex III in both crude tissue homogenate and isolated mitochondria of liver, heart, skeletal muscle and brain.
This spectrophotometric assay is sensitive, and specific for complex III activity because of the negligible blank rate and high antimycin A-sensitive activity. The low concentration of bovine serum albumin, and the use of inexpensive detergent Tween-20 make this improved method more robust for its use in a clinical laboratory setting.
组织样本中复合物III活性的测定为线粒体疾病及与线粒体功能障碍相关疾病的诊断提供了关键证据。然而,由于使用了不同的检测方法,文献中出现了很大的差异。
研究了一种改进的分光光度法的反应条件,该方法对复合物III活性的特异性高于目前使用的方法。
确定了最佳条件,即使用0.01%的牛血清白蛋白和0.05%的吐温-20。与以前的方法相比,本方法具有更多的抗霉素A敏感的复合物III活性。因此,这种改进的方法灵敏且适用于检测肝脏、心脏、骨骼肌和脑的粗组织匀浆及分离线粒体中的复合物III。
这种分光光度法灵敏且对复合物III活性具有特异性,因为空白率可忽略不计且抗霉素A敏感活性高。低浓度的牛血清白蛋白以及使用廉价的去污剂吐温-20使这种改进的方法在临床实验室环境中使用时更稳定。