Slaughterhouse wastewaters contain varied and high amounts of organic matter (e.g., proteins, blood, fat). In order to produce an effluent suitable for stream discharge, electrochemical techniques have been particularly explored at the laboratory pilot scale for organic compounds removal from poultry slaughterhouse (PS) effluent. Electrocoagulation (EC) process was tested using either mild steel or aluminium electrodes arranged in bipolar (BP) or monopolar configuration system. Results showed that the best performance was obtained using mild steel BP electrode system operated at a current intensity of 0.3A, through 60 or 90 min of treatment. Under these conditions, removals of 86+/-1% and 99+/-1% were measured for BOD and oil and grease, respectively, whereas soluble COD and total COD were removed by 50+/-4% and 82+/-2%, respectively. EC is also efficient for decolorization (red-color) and clarification of the PS effluent. Removals of 89+/-4% and 90+/-4% have been measured for total suspended solids and turbidity, respectively. Electrochemical coagulation operated under the optimal conditions involves a total cost of 0.71 USD $ per cubic meter of treated PS effluent. This cost includes energy and electrode consumptions, chemicals, and sludge disposal.
屠宰场废水含有大量种类各异的有机物(如蛋白质、血液、脂肪)。为了产生适合排入河流的废水,实验室中试规模特别探索了用电化学技术去除家禽屠宰场(PS)废水中的有机化合物。使用布置成双极(BP)或单极配置系统的低碳钢或铝电极对电凝聚(EC)工艺进行了测试。结果表明,使用低碳钢BP电极系统,在电流强度为0.3A的条件下运行60或90分钟,可获得最佳性能。在此条件下,测得生化需氧量(BOD)和油脂的去除率分别为86±1%和99±1%,而可溶性化学需氧量(COD)和总化学需氧量的去除率分别为50±4%和82±2%。电凝聚对于PS废水的脱色(红色)和澄清也很有效。测得总悬浮固体和浊度的去除率分别为89±4%和90±4%。在最佳条件下运行的电化学凝聚处理每立方米PS废水的总成本为0.71美元。该成本包括能源、电极消耗、化学品和污泥处置费用。