Xiong Guoming, Rogers D W O
Physics Department, Carleton University, Ottawa, Ontario K1S 5B6, Canada.
Med Phys. 2008 May;35(5):2104-9. doi: 10.1118/1.2905028.
The relationship between the photon beam quality specifier %dd(10)x and the Spencer-Attix water water to air restricted mass collision stopping-power ratio, (L/rho))air(water), is studied using Monte Carlo simulation with realistic beams in contrast to the previously used realistic but uniform spectra from an isotropic point source. The differences between accelerators with and without flattening filters are investigated since flattening filter free accelerators appear to be useful for IMRT. Our results show that the standard relationship between %dd(10)x and (L/rho)air(water), which is used in the TG-51 protocol to calculate the quality conversion factor kQ, is acceptable for beams with or without a flattening filter with a maximum error of 0.4%, although a fit to the new data would reduce the maximum error to 0.2%. Reasons for differences between the individual values of %dd(10)x and (L/ rho)air(water) with and without a flattening filter are studied. Specifically the differences due to the softening of the beam, the change in shape of the profile, and the inclusion of radial variations in the photon energy spectra, are investigated. It is shown that if TPR10(20) is used as a beam quality specifier, there are two different relationships between TPR10(20) and (L/rho)air(water) which differ by 0.4%-1%. When using TPR10(20) as a beam quality specifier in a beam without a flattening filter, one should subtract 0.5% from the value of kQ for a given value of TPR10(20).
通过蒙特卡罗模拟研究了光子束质量指定参数%dd(10)x与斯宾塞 - 阿蒂克斯水对空气的受限质量碰撞阻止本领比(L/ρ)air(water)之间的关系,所使用的是实际光束,这与之前使用的来自各向同性点源的实际但均匀的光谱不同。研究了有无均整滤过器的加速器之间的差异,因为无均整滤过器的加速器似乎对调强放射治疗有用。我们的结果表明,TG - 51协议中用于计算质量转换因子kQ的%dd(10)x与(L/ρ)air(water)之间的标准关系,对于有无均整滤过器的光束都是可接受的,最大误差为0.4%,不过对新数据进行拟合会将最大误差降至0.2%。研究了有无均整滤过器时%dd(10)x和(L/ρ)air(water)各个值之间存在差异的原因。具体研究了由于光束软化、剖面形状变化以及光子能谱中包含径向变化所导致的差异。结果表明,如果将组织体模比TPR10(20)用作光束质量指定参数,TPR10(20)与(L/ρ)air(water)之间存在两种不同的关系,相差0.4% - 1%。在无均整滤过器的光束中使用TPR10(20)作为光束质量指定参数时,对于给定的TPR10(20)值,应从kQ值中减去0.5%。