Suppr超能文献

Conductive polymer as a controlled microenvironment for the potentiometric high-throughput evaluation of ionic liquid cell toxicity.

作者信息

Qiu Weilian, Zeng Xiangqun

机构信息

Chemistry Department, Oakland University, Rochester, MI 48309, USA.

出版信息

Anal Bioanal Chem. 2008 Sep;392(1-2):203-13. doi: 10.1007/s00216-008-2263-x. Epub 2008 Jul 19.

Abstract

This paper presents both biological and potentiometric evaluations of the cell toxicity of a widely used ionic liquid, 1-butyl-3-methylimidazolium tetrafluoroborate ([bmim]BF(4)), to Chinese hamster lung fibroblast cells (V79 cell line). The innovative potentiometric study takes advantage of the unique properties of conductive polymer polypyrrole (PPY) for the potentiometric evaluation of cell toxicity of [bmim]BF(4) to the V79 cells in a real-time, noninvasive and high-throughput manner. The conductive polymer PPY provides a controlled microenvironment that allows the quantitative release of the anions of the ionic liquids into the cells being monitored in real time and noninvasively. Parallel biological assay results showed that V79 cells exposed to [bmim]BF(4) usually grew in clusters, and that many small vacuoles could be seen in the cytoplasm. At the 24th hour after the V79 cells had been exposed to the ionic liquid (IL), the half inhibition concentration (EC(50)) of [bmim]BF(4) was around 5 mM. From a cell cycle study performed using a FACScan flow cytometer, it was found that the V79 cells could be partially locked to the G(1) phase by [bmim]BF(4), which extended the doubling time for cell growth. Comparing with the EC(50) values of cadmium chloride and mercury chloride, [bmim]BF(4) is not very toxic, but it may have a long-term toxic effect on mammalian cells. Compared to traditional biological in vitro assays, the use of a conductive polymer substrate in combination with a potentiometric sensor array is much more sensitive, faster, and enables a simpler evaluation of chemical cell toxicity. Additionally, it simplifies the study of the reversibility of cell toxicity, i.e., cell recovery, because there is no need to refresh the culture medium since a finite amount of chemicals can be doped and released. We found that the cytotoxicity of [bmim]BF(4) at a concentration of less than 6 mM was reversible for the V79 cell line, because cell morphology and proliferation rate returned to normal after the removal of the IL from the culture medium. This finding suggests that the IL [bmim]BF(4) could be used as a tool to control mammalian cell proliferation rate.

摘要

相似文献

1
Conductive polymer as a controlled microenvironment for the potentiometric high-throughput evaluation of ionic liquid cell toxicity.
Anal Bioanal Chem. 2008 Sep;392(1-2):203-13. doi: 10.1007/s00216-008-2263-x. Epub 2008 Jul 19.
5
Potentiometric biosensor for studying hydroquinone cytotoxicity in vitro.用于研究体外对苯二酚细胞毒性的电位生物传感器。
Biosens Bioelectron. 2010 Feb 15;25(6):1356-62. doi: 10.1016/j.bios.2009.10.027. Epub 2009 Oct 27.

引用本文的文献

1
Potentiometric biosensor for studying hydroquinone cytotoxicity in vitro.用于研究体外对苯二酚细胞毒性的电位生物传感器。
Biosens Bioelectron. 2010 Feb 15;25(6):1356-62. doi: 10.1016/j.bios.2009.10.027. Epub 2009 Oct 27.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验