Accuracy of ultrasound-guided versus fluoroscopically guided contrast-controlled piriformis injections: a cadaveric study.

作者信息

Finnoff Jonathan T, Hurdle Mark Friedrich B, Smith Jay

机构信息

Department of Physical Medicine and Rehabilitation, College of Medicine, Mayo Clinic, 200 First St SW, Rochester, MN 55902, USA.

出版信息

J Ultrasound Med. 2008 Aug;27(8):1157-63. doi: 10.7863/jum.2008.27.8.1157.

Abstract

OBJECTIVE

The purpose of this study was to compare the accuracy of ultrasound-guided piriformis injections with fluoroscopically guided contrast-controlled piriformis injections in a cadaveric model.

METHODS

Twenty piriformis muscles in 10 unembalmed cadavers were injected with liquid latex using both fluoroscopically guided contrast-controlled and US-guided injection techniques. All injections were performed by the same experienced individual. Two different colors of liquid latex were used to differentiate injection placement for each procedure, and the injection order was randomized. The gluteal regions were subsequently dissected by an individual blinded to the injection technique. Colored latex seen within the piriformis muscle, sheath, or both was considered an accurate injection.

RESULTS

Nineteen of 20 ultrasound-guided injections (95%) correctly placed the liquid latex within the piriformis muscle, whereas only 6 of the 20 fluoroscopically guided contrast-controlled injections (30%) were accurate (P = .001). The liquid latex in 13 of the 14 missed fluoroscopically guided contrast-controlled piriformis injections and the single missed ultrasound-guided injection was found within the gluteus maximus muscle. In the single remaining missed fluoroscopically guided contrast-controlled piriformis injection, the liquid latex was found within the sciatic nerve.

CONCLUSIONS

In this cadaveric model, ultrasound-guided piriformis injections were significantly more accurate than fluoroscopically guided contrast-controlled injections. Despite the use of bony landmarks and contrast, most of the fluoroscopically attempted piriformis injections were placed superficially within the gluteus maximus. Clinicians performing piriformis injections should be aware of the potential pitfalls of fluoroscopically guided contrast-controlled piriformis injections and consider using ultrasound guidance to ensure correct needle placement.

摘要

目的

本研究旨在比较在尸体模型中超声引导下梨状肌注射与透视引导下对比剂控制的梨状肌注射的准确性。

方法

使用透视引导下对比剂控制注射技术和超声引导注射技术,对10具未防腐尸体的20条梨状肌注射液体乳胶。所有注射均由同一位经验丰富的人员进行。使用两种不同颜色的液体乳胶来区分每种操作的注射位置,且注射顺序是随机的。随后由对注射技术不知情的人员解剖臀区。在梨状肌、肌鞘或两者中见到的彩色乳胶被视为准确注射。

结果

20次超声引导注射中有19次(95%)将液体乳胶正确注入梨状肌内,而20次透视引导下对比剂控制注射中只有6次(30%)准确(P = .001)。在14次未成功的透视引导下对比剂控制梨状肌注射中的13次以及唯一一次未成功的超声引导注射中,液体乳胶位于臀大肌内。在剩余唯一一次未成功的透视引导下对比剂控制梨状肌注射中,液体乳胶位于坐骨神经内。

结论

在本尸体模型中,超声引导下梨状肌注射比透视引导下对比剂控制注射明显更准确。尽管使用了骨性标志和对比剂,但大多数透视引导下尝试的梨状肌注射都浅置于臀大肌内。进行梨状肌注射的临床医生应意识到透视引导下对比剂控制梨状肌注射的潜在陷阱,并考虑使用超声引导以确保正确的进针位置。