Suppr超能文献

双源CT用于心率较高的心脏移植患者冠状动脉的可视化。

Dual-source CT for visualization of the coronary arteries in heart transplant patients with high heart rates.

作者信息

Bastarrika Gorka, De Cecco Carlo Nicola, Arraiza Maria, Mastrobuoni Stefano, Pueyo Jesús C, Ubilla Matias, Rábago Gregorio

机构信息

Department of Radiology, Clínica Universitaria, Universidad de Navarra, Ave. Pío XII, 36, 31008 Pamplona, Spain.

出版信息

AJR Am J Roentgenol. 2008 Aug;191(2):448-54. doi: 10.2214/AJR.07.3512.

Abstract

OBJECTIVE

The purpose of this study was to evaluate the quality of dual-source CT images of the coronary arteries in heart transplant recipients with high heart rates.

SUBJECTS AND METHODS

Contrast-enhanced dual-source CT coronary angiography was performed on 23 heart transplant recipients (20 men, three women; mean age, 61.1 +/- 12.8 years). Data sets were reconstructed in 5% steps from 30% to 80% of the R-R interval. Two blinded independent readers using a 5-point scale (0, not evaluative; 4, excellent quality) assessed the quality of images of coronary segments.

RESULTS

The mean heart rate during scanning was 89.2 +/- 10.4 beats/min. Interobserver agreement on the quality of images of the whole coronary tree was a kappa value of 0.78 and for selection of the optimal reconstruction interval was a kappa value of 0.82. The optimal reconstruction interval was systole in 17 (74%) of the 23 of heart transplant recipients. At the best reconstruction interval, diagnostic image quality (score >or= 2) was obtained in 92.1% (303 of 329) of the coronary artery segments. The mean image quality score for the whole coronary tree was 3.1 +/- 1.01. No significant correlation between mean heart rate (rho = 0.31) or heart rate variability (rho = 0.23) and overall image quality score was observed (p = not significant).

CONCLUSION

Dual-source CT acquisition yields coronary angiograms of diagnostic quality in heart transplant recipients. Mean heart rate and heart rate variability during scanning do not have a negative effect on the overall quality of images of the coronary arteries.

摘要

目的

本研究旨在评估心率较高的心脏移植受者冠状动脉双源CT图像的质量。

对象与方法

对23例心脏移植受者(20例男性,3例女性;平均年龄61.1±12.8岁)进行了对比增强双源CT冠状动脉造影。数据集在R-R间期的30%至80%范围内以5%的步长重建。两名独立的盲法阅片者使用5分制(0分,不可评估;4分,图像质量极佳)对冠状动脉节段图像质量进行评估。

结果

扫描期间的平均心率为89.2±10.4次/分钟。两位阅片者对整个冠状动脉树图像质量的一致性kappa值为0.78,对最佳重建间期选择的一致性kappa值为0.82。23例心脏移植受者中有17例(74%)的最佳重建间期为收缩期。在最佳重建间期,92.1%(329个冠状动脉节段中的303个)的冠状动脉节段获得了诊断性图像质量(评分≥2分)。整个冠状动脉树的平均图像质量评分为3.1±1.01。未观察到平均心率(rho=0.31)或心率变异性(rho=0.23)与整体图像质量评分之间存在显著相关性(p=无显著性差异)。

结论

双源CT采集可为心脏移植受者提供具有诊断质量的冠状动脉造影图像。扫描期间的平均心率和心率变异性对冠状动脉图像的整体质量没有负面影响。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验