Suppr超能文献

距下关节中立位的评估:一项尸体研究。

Assessment of subtalar joint neutral position: a cadaveric study.

作者信息

Chen Yan-xi, Yu Guang-rong, Mei Jiong, Zhou Jia-qian, Wang Wen

机构信息

Department of Orthopaedics, Tongji Hospital of Tongji University, Shanghai 200065, China.

出版信息

Chin Med J (Engl). 2008 Apr 20;121(8):735-9.

Abstract

BACKGROUND

Subtalar joint (STJ) neutral position is the position typically used by clinicians to obtain a cast representation of a patient's foot before fabrication of biomechanical functional orthosis. But no method for measuring STJ neutral position has been proven accurate and reproducible by different testers. This study was conducted to investigate the STJ neutral position in normal feet in cadavers.

METHODS

Twelve fresh-frozen specimens of amputated lower legs were used. Pressure-sensitive films were inserted into the anterior and posterior articulation of STJ. The contact areas for various foot positions and under axial loads of 600 N were determined based on the gray level of the digitized film. The STJ neutral positions were determined as the ankle-foot position where the maximum contact area was achieved, because the neutral position of a joint was defined as the position where the concave and convex surfaces were completely congruous.

RESULTS

In ankle-foot neutral position, the contact area of STJ was (2.79 +/- 0.24) cm(2). In the range of motion of adduction-abduction (ADD-ABD), the maximum contact area was (3.00 +/- 0.26) cm(2) when the foot was positioned 10 degrees of ABD (F = 221.361, P < 0.05). In the range of motion of dorsiflexion-plantarflexion (DF-PF), the maximum contact area was (3.61 +/- 0.25) cm(2) when the foot was positioned 20 degrees of DF (F = 121.067, P < 0.05). In the range of motion of inversion-eversion (INV-EV), the maximum contact area was (3.14 +/- 0.26) cm(2) when the foot was positioned 10 degrees of EV (F = 256.252, P < 0.05).

CONCLUSIONS

Joints, such as STJ, therefore, are not necessarily in neutral position when the ankle-foot is placed in the traditional concept of neutral position. The results demonstrate that the most approximate STJ neutral position was in the foot position of 10 degrees of abduction, 20 degrees of dorsiflexion and 10 degrees of eversion.

摘要

背景

距下关节(STJ)中立位是临床医生在制作生物力学功能性矫形器之前获取患者足部石膏模型时通常采用的位置。但尚无测量STJ中立位的方法被不同测试者证明准确且可重复。本研究旨在调查尸体正常足部的STJ中立位。

方法

使用12个新鲜冷冻的小腿截肢标本。将压敏膜插入STJ的前后关节。根据数字化膜的灰度确定不同足部位置以及600N轴向载荷下的接触面积。由于关节的中立位被定义为凹凸表面完全吻合的位置,因此将STJ中立位确定为达到最大接触面积时的踝足位置。

结果

在踝足中立位时,STJ的接触面积为(2.79±0.24)cm²。在内收 - 外展(ADD - ABD)运动范围内,当足部处于外展10度时,最大接触面积为(3.00±0.26)cm²(F = 221.361,P < 0.05)。在背屈 - 跖屈(DF - PF)运动范围内,当足部处于背屈20度时,最大接触面积为(3.61±0.25)cm²(F = 121.067,P < 0.05)。在旋前 - 旋后(INV - EV)运动范围内,当足部处于旋后10度时,最大接触面积为(3.14±0.26)cm²(F = 256.252,P < 0.05)。

结论

因此,当踝足处于传统概念的中立位时,诸如STJ之类的关节不一定处于中立位。结果表明,最接近STJ中立位的足部位置是外展10度、背屈20度和旋后10度。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验