Wang C L, Cheng C K, Chen C W, Lu C M, Hang Y S, Liu T K
Department of Orthopedic Surgery, National Taiwan University, Taipei.
J Biomech. 1995 Mar;28(3):269-79. doi: 10.1016/0021-9290(94)00076-g.
We investigated how foot position and ankle arthrodesis affect the contact characteristics of the subtalar joint. Nine fresh-frozen specimens of amputated lower legs were used. Pressure-sensitive films were inserted into the anterior and posterior articulation of the subtalar joint. The contact areas and pressure for various foot positions and under axial loads of 600, 1200, and 1800 N were determined based on the gray level of the digitized film. In neutral position and under a 600 N load, the maximum contact pressure in the subtalar joint was 5.13 +/- 1.16 MPa. The contact area (1.18 +/- 0.35 cm2) was only 12.7% of the whole subtalar articulation area (9.31 +/- 0.66 cm2), and the total force (348.5 +/- 41.7 N) transmitted via this contact area was about 58% of the applied load (600 N). Dorsiflexion of the foot increased the contact area and the force transmitted, but decreased the average contact pressure in the subtalar joint, while the reverse occurred in plantar flexion. Eversion increased the subtalar contact stress, whereas inversion up to 10 degrees decreased it. Ankle joint arthrodesis shifted the contact areas in the subtalar joint posteriorly in all inversion/eversion positions. Moreover, total force transmitted through the subtalar joint as well as the contact pressure increased.
我们研究了足部位置和踝关节融合如何影响距下关节的接触特性。使用了9个新鲜冷冻的小腿截肢标本。将压敏膜插入距下关节的前后关节处。根据数字化膜的灰度确定不同足部位置以及在600、1200和1800 N轴向载荷下的接触面积和压力。在中立位和600 N载荷下,距下关节的最大接触压力为5.13±1.16 MPa。接触面积(1.18±0.35 cm²)仅占整个距下关节面积(9.31±0.66 cm²)的12.7%,通过该接触面积传递的总力(348.5±41.7 N)约为施加载荷(600 N)的58%。足部背屈增加了接触面积和传递的力,但降低了距下关节的平均接触压力,而跖屈时情况相反。外翻增加了距下关节接触应力,而内翻达10度时则降低了接触应力。踝关节融合使距下关节在所有内翻/外翻位置的接触面积向后移位。此外,通过距下关节传递的总力以及接触压力均增加。