Beerten Koen, Vanhavere Filip
SCK.CEN, Radiation Protection Dosimetry and Calibration, Boeretang 200, 2400 Mol, Belgium.
Radiat Prot Dosimetry. 2008;131(4):509-12. doi: 10.1093/rpd/ncn212. Epub 2008 Aug 14.
The use of a portable electronic device in accident dosimetry has been investigated. The thermoluminescence properties of a surface-mount alumina-rich ceramic resonator from a USB flash drive were investigated. The following characteristics were verified: the absence of a zero-dose signal, gamma dose response, dose recycling behaviour, fading and optical bleaching. Finally, this component has been successfully used to determine a simulated accident dose (1 d following the irradiation event). It is concluded that it should be possible to perform rapid and reliable accident dose assessments with such components using conventional thermoluminescence dosimetry equipment.