Beuer Florian, Steff Bastian, Naumann Michael, Sorensen John A
Department of Prosthodontics, Ludwig-Maximilians-University, Munich, Germany.
Eur J Oral Sci. 2008 Aug;116(4):381-6. doi: 10.1111/j.1600-0722.2008.00551.x.
The purpose of this in vitro study was to compare the load-bearing capacity of posterior three-unit fixed dental prostheses (FDP) produced with three different all-ceramic framework materials: glass-infiltrated alumina (ICA), glass-infiltrated alumina strengthened with zirconia (ICZ), and yttria-stabilized polycrystalline zirconia (YZ). Additionally, the influence on aging of mechanical cyclic fatigue loading and thermal cycling in water were evaluated. A total of 20 frameworks each were fabricated from ICA, ICZ, and YZ by a computer-aided design (CAD)/computer-aided manufacturing (CAM) system. The framework designs were identical for all specimens. All frameworks were veneered with porcelain and cemented with glass-ionomer. Prior to fracture testing, 10 FDP of each experimental group were subjected to thermal and mechanical cycling. Additionally, fractographic analysis was performed. Statistical analysis showed that FDP made from YZ had significantly higher load to failure, whereas no difference was found between the other two materials. Aging did not have a significant effect on the fracture load.
本体外研究的目的是比较用三种不同全瓷框架材料制作的后牙三单位固定义齿(FDP)的承载能力:玻璃渗透氧化铝(ICA)、用氧化锆增强的玻璃渗透氧化铝(ICZ)和氧化钇稳定的多晶氧化锆(YZ)。此外,还评估了机械循环疲劳加载和水中热循环对老化的影响。通过计算机辅助设计(CAD)/计算机辅助制造(CAM)系统,分别用ICA、ICZ和YZ制作了总共20个框架。所有标本的框架设计相同。所有框架均用瓷贴面并用玻璃离子粘固剂粘固。在断裂测试之前,对每个实验组的10个FDP进行热循环和机械循环。此外,还进行了断口分析。统计分析表明,由YZ制成的FDP的失效载荷显著更高,而其他两种材料之间未发现差异。老化对断裂载荷没有显著影响。