Suppr超能文献

复合树脂和长石质全瓷CAD/CAM冠的断裂载荷。

Fracture load of composite resin and feldspathic all-ceramic CAD/CAM crowns.

作者信息

Attia Ahmed, Abdelaziz Khalid M, Freitag Sandra, Kern Matthias

机构信息

Department of Conservative Dentistry and Fixed Prosthodontics, Faculty of Dentistry, Mansoura University, Egypt.

出版信息

J Prosthet Dent. 2006 Feb;95(2):117-23. doi: 10.1016/j.prosdent.2005.11.014.

Abstract

STATEMENT OF PROBLEM

Various machinable materials are currently used with computer-aided design/computer-assisted manufacturing (CAD/CAM) technologies for the chairside fabrication of restorations. However, properties of these new machinable materials, such as fracture load, wear, marginal deterioration, and color stability, should be investigated in vitro under replicated clinical conditions prior to time-consuming clinical studies.

PURPOSE

This study investigated the effect of cyclic loading fatigue and different luting agents under wet conditions on the fracture load of CAD/CAM machined composite resin and all-ceramic crowns.

MATERIALS AND METHODS

Ninety-six intact human maxillary premolars were prepared for composite resin and all-ceramic crowns with the following preparation criteria: 6-degree axial taper, 1.5-mm shoulder finish line placed 0.5 mm occlusal to the cemento-enamel junction, 1.5-mm axial reduction, 2-mm occlusal reduction, and 5-mm occluso-gingival height. Sixteen unprepared premolars served as controls. Forty-eight all-ceramic crowns (Vita Mark II) and 48 millable composite resin crowns (MZ100 Block) were fabricated using a CAD/CAM system (Cerec 3). Three luting agents-RelyX ARC (RX), GC Fuji CEM (FC), and zinc phosphate cement (ZP)-were used for cementation (n = 16). After 1-week storage in water, half of the specimens (n=8) in each subgroup were cyclically loaded and thermal cycled under wet conditions for 600,000 masticatory cycles and 3500 thermal cycles (58 degrees C/4 degrees C; dwell time, 60 seconds) in a masticatory simulator; the other half (n = 8) were fractured without cyclic loading. All specimens were loaded in a universal testing machine with a compressive load (N) applied along the long axis of the specimen at a crosshead speed of 1 mm/min until fracture. Fracture loads (N) were recorded for each specimen. Three-way analysis of variance was used to detect the effects of the experimental factors (crown material, luting agent, and loading conditions) on the fracture load. The comparison with the unprepared natural teeth as controls was done by means of t tests (alpha=.05).

RESULTS

Analysis of variance revealed a statistically significant influence of the luting agent and the cyclic loading (P < .001), whereas the crown material had no significant influence. Cyclic loading fatigue significantly decreased the mean fracture load of test groups independent of the 3 luting agents used: MZ100/ZP, 827.1 to 552.5 N; MZ100/FC, 914.7 to 706.2 N; MZ100/RX, 955.9 to 724.4 N; Vita/ZP, 772.3 to 571.5 N; Vita/FC, 923.6 to 721.1 N; and Vita/RX, 929.1 to 752.7 N. However, there was no significant difference in the mean fracture load of control specimens before and after cyclic loading (1140.1 N and 1066.2 N, respectively). Adhesive luting agents RelyX ARC and GC Fuji CEM increased fracture load significantly compared to zinc phosphate cement.

CONCLUSIONS

Cyclic loading fatigue significantly reduced the fracture loads of composite resin and all-ceramic crowns, whereas adhesive cementation significantly increased the fracture loads.

摘要

问题陈述

目前,各种可加工材料与计算机辅助设计/计算机辅助制造(CAD/CAM)技术一起用于椅旁修复体制作。然而,在进行耗时的临床研究之前,应在体外模拟临床条件下研究这些新型可加工材料的性能,如断裂载荷、磨损、边缘劣化和颜色稳定性。

目的

本研究调查了循环加载疲劳和不同粘结剂在潮湿条件下对CAD/CAM加工的复合树脂全瓷冠断裂载荷的影响。

材料与方法

按照以下预备标准,为96颗完整的人上颌前磨牙预备复合树脂全瓷冠:轴壁锥度6度,在牙骨质-釉质界上方0.5mm处制备1.5mm宽的肩台边缘,轴面预备1.5mm,咬合面预备2mm,牙合龈高度5mm。16颗未预备的前磨牙作为对照。使用CAD/CAM系统(Cerec 3)制作48颗全瓷冠(Vita Mark II)和48颗可切削复合树脂冠(MZ100 Block)。使用三种粘结剂——RelyX ARC(RX)、GC Fuji CEM(FC)和磷酸锌水门汀(ZP)——进行粘结(n = 16)。在水中储存1周后,每个亚组中的一半标本(n = 8)在潮湿条件下于咀嚼模拟器中进行循环加载和热循环,模拟600,000次咀嚼循环和3500次热循环(58℃/4℃;保持时间60秒);另一半(n = 8)不进行循环加载直接测试其断裂强度。所有标本在万能试验机上沿标本长轴以1mm/min的十字头速度施加压缩载荷(N)直至断裂。记录每个标本的断裂载荷(N)。采用三因素方差分析检测实验因素(冠材料、粘结剂和加载条件)对断裂载荷的影响。通过t检验将其与未预备的天然牙对照进行比较(α = 0.05)。

结果

方差分析显示粘结剂和循环加载对断裂载荷有统计学显著影响(P < 0.001),而冠材料无显著影响。循环加载疲劳显著降低了测试组的平均断裂载荷,与使用的三种粘结剂无关:MZ100/ZP组从827.1N降至552.5N;MZ100/FC组从914.7N降至706.2N;MZ100/RX组从955.9N降至724.4N;Vita/ZP组从772.3N降至571.5N;Vita/FC组从923.6N降至721.1N;Vita/RX组从929.1N降至752.7N。然而,循环加载前后对照标本的平均断裂载荷无显著差异(分别为1140.1N和1066.2N)。与磷酸锌水门汀相比,粘结剂RelyX ARC和GC Fuji CEM显著提高了断裂载荷。

结论

循环加载疲劳显著降低了复合树脂全瓷冠的断裂载荷,而粘结固位显著提高了断裂载荷。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验