Suppr超能文献

Positive contrast visualization of nitinol devices using susceptibility gradient mapping.

作者信息

Vonken Evert-jan P A, Schär Michael, Stuber Matthias

机构信息

Russell H Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.

出版信息

Magn Reson Med. 2008 Sep;60(3):588-94. doi: 10.1002/mrm.21688.

Abstract

MRI visualization of devices is traditionally based on signal loss due to T(2)* effects originating from local susceptibility differences. To visualize nitinol devices with positive contrast, a recently introduced postprocessing method is adapted to map the induced susceptibility gradients. This method operates on regular gradient-echo MR images and maps the shift in k-space in a (small) neighborhood of every voxel by Fourier analysis followed by a center-of-mass calculation. The quantitative map of the local shifts generates the positive contrast image of the devices, while areas without susceptibility gradients render a background with noise only. The positive signal response of this method depends only on the choice of the voxel neighborhood size. The properties of the method are explained and the visualizations of a nitinol wire and two stents are shown for illustration.

摘要

相似文献

1
Positive contrast visualization of nitinol devices using susceptibility gradient mapping.
Magn Reson Med. 2008 Sep;60(3):588-94. doi: 10.1002/mrm.21688.
2
Susceptibility-based MR Imaging of Nitinol Stent.
Annu Int Conf IEEE Eng Med Biol Soc. 2019 Jul;2019:5753-5756. doi: 10.1109/EMBC.2019.8856775.
3
Positive visualization of implanted devices with susceptibility gradient mapping using the original resolution.
Magn Reson Med. 2011 May;65(5):1483-90. doi: 10.1002/mrm.22710. Epub 2010 Dec 16.
5
Positive visualization of MR-compatible nitinol stent using a susceptibility-based imaging technique.
Quant Imaging Med Surg. 2019 Mar;9(3):477-490. doi: 10.21037/qims.2019.03.15.
7
Potential applications of the quantitative susceptibility mapping (QSM) in MR-guided radiation therapy.
Phys Med Biol. 2019 Jul 16;64(14):145013. doi: 10.1088/1361-6560/ab2623.
9
10

引用本文的文献

1
Positive visualization of MR-compatible nitinol stent using a susceptibility-based imaging technique.
Quant Imaging Med Surg. 2019 Mar;9(3):477-490. doi: 10.21037/qims.2019.03.15.
2
Positive Contrast MRI Techniques for Visualization of Iron-Loaded Hernia Mesh Implants in Patients.
PLoS One. 2016 May 18;11(5):e0155717. doi: 10.1371/journal.pone.0155717. eCollection 2016.
3
Direct in vitro comparison of six three-dimensional positive contrast methods for susceptibility marker imaging.
J Magn Reson Imaging. 2013 Aug;38(2):344-57. doi: 10.1002/jmri.23976. Epub 2012 Dec 19.
4
Positive contrast visualization of SPIO-labeled pancreatic islets using echo-dephased steady-state free precession.
Eur Radiol. 2011 Jan;21(1):214-20. doi: 10.1007/s00330-010-1909-1. Epub 2010 Aug 5.
6
Utilizing different methods for visualizing susceptibility from a single multi-gradient echo dataset.
MAGMA. 2009 Oct;22(5):297-308. doi: 10.1007/s10334-009-0180-4. Epub 2009 Jul 31.
7
Echo-dephased steady state free precession.
MAGMA. 2009 Oct;22(5):277-85. doi: 10.1007/s10334-009-0173-3. Epub 2009 May 16.

本文引用的文献

3
Dephased MRI.
Magn Reson Med. 2006 Jan;55(1):92-7. doi: 10.1002/mrm.20733.
4
Cellular MR imaging.
Mol Imaging. 2005 Jul-Sep;4(3):143-64. doi: 10.1162/15353500200505145.
5
Positive contrast magnetic resonance imaging of cells labeled with magnetic nanoparticles.
Magn Reson Med. 2005 May;53(5):999-1005. doi: 10.1002/mrm.20477.
6
Cardiac SSFP imaging at 3 Tesla.
Magn Reson Med. 2004 Apr;51(4):799-806. doi: 10.1002/mrm.20024.
7
Passive tracking exploiting local signal conservation: the white marker phenomenon.
Magn Reson Med. 2003 Oct;50(4):784-90. doi: 10.1002/mrm.10574.
8
MR imaging in the presence of vascular stents: A systematic assessment of artifacts for various stent orientations, sequence types, and field strengths.
J Magn Reson Imaging. 2000 Oct;12(4):606-15. doi: 10.1002/1522-2586(200010)12:4<606::aid-jmri14>3.0.co;2-j.
9
Linear combination steady-state free precession MRI.
Magn Reson Med. 2000 Jan;43(1):82-90. doi: 10.1002/(sici)1522-2594(200001)43:1<82::aid-mrm10>3.0.co;2-9.
10
Theory and application of static field inhomogeneity effects in gradient-echo imaging.
J Magn Reson Imaging. 1997 Mar-Apr;7(2):266-79. doi: 10.1002/jmri.1880070203.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验