Iwata Miyoko, Ohno Sadanori, Kawai Tetsuji, Ichijima Hideji, Cavanagh H Dwight
Menicon Co, Ltd, Nagoya, Japan.
Eye Contact Lens. 2008 Sep;34(5):272-80. doi: 10.1097/ICL.0b013e318182f357.
To establish a new analytical method using gas chromatography/mass spectrometry (GC/MS) for evaluating the lipids adsorbed on silicone hydrogel (SH) contact lenses: cholesterol, cholesterol ester, wax, and squalene.
A novel GC/MS method was developed and validated for the repeatability, specificity, linearity, detection and quantitation limits, and percentage recovery. The lipids in an artificial tear solution were adsorbed on 5 SH lenses (asmofilcon A, balafilcon A, galyfilcon A, lotrafilcon A, and lotrafilcon B) and 1 conventional hydrogel lens (etafilcon A) in vitro. The lipids adsorbed were then extracted and analyzed by the GC/MS method.
Repeatability of this analytical method was less than 2.2% deviation for all test lipids; however, the analytes were completely discriminated with sharp peak shapes, and identified specifically. The correlation coefficient showing linearity was at least 0.991 under 50 microg/mL of lipid concentration. Detection and quantitation limits were statistically 0.5 to 0.8 microg/mL and 1.4 to 2.5 microg/mL, respectively, for all analytes. Percentage recovery was estimated as approximately 80% for 3 microg/lens, 90% for 5 microg/lens, and almost 100% for larger amounts of lipids. Quantitatively, the lipids absorbed on contact lenses were lotrafilcon A = (near equal) lotrafilcon B = (near equal) etafilcon A < asmofilcon A < galyfilcon A = (near equal) balafilcon A with the value of 0.4 to 7.6 microg/lens. Lipid adsorption on SH lenses varied depending on the lipid components and lens surface properties.
The GC/MS method established in this study is excellent for the repeatability, specificity, linearity, detection and quantitation limits, and percentage recovery, and provides a novel highly sensitive and useful tool for evaluating lipids adsorbed on SH lenses.
建立一种使用气相色谱/质谱联用仪(GC/MS)评估吸附在硅水凝胶(SH)隐形眼镜上的脂质(胆固醇、胆固醇酯、蜡和角鲨烯)的新分析方法。
开发了一种新型GC/MS方法,并对其重复性、特异性、线性、检测限和定量限以及回收率进行了验证。人工泪液中的脂质在体外吸附到5种SH镜片(asmofilcon A、balafilcon A、galyfilcon A、lotrafilcon A和lotrafilcon B)和1种传统水凝胶镜片(etafilcon A)上。然后提取吸附的脂质,并用GC/MS方法进行分析。
该分析方法对所有测试脂质的重复性偏差小于2.2%;然而,分析物以尖锐的峰形完全区分,并得到特异性鉴定。在脂质浓度低于50μg/mL时,显示线性的相关系数至少为0.991。所有分析物的检测限和定量限经统计分别为0.5至0.8μg/mL和1.4至2.5μg/mL。对于3μg/镜片,回收率估计约为80%;对于5μg/镜片,回收率约为90%;对于大量脂质,回收率几乎为100%。定量分析,吸附在隐形眼镜上的脂质为lotrafilcon A =(近似相等)lotrafilcon B =(近似相等)etafilcon A < asmofilcon A < galyfilcon A =(近似相等)balafilcon A,值为0.4至7.6μg/镜片。SH镜片上的脂质吸附因脂质成分和镜片表面性质而异。
本研究建立的GC/MS方法在重复性、特异性、线性、检测限和定量限以及回收率方面表现出色,为评估吸附在SH镜片上的脂质提供了一种新型高灵敏度且有用的工具。