Kobayashi Yasuko, Yanai Ryoji, Chikamoto Nobuhiko, Chikama Tai-Ichiro, Ueda Kiichi, Nishida Teruo
Department of Ophthalmology, Yamaguchi University Graduate School of Medicine, Ube City, Yamaguchi, Japan.
Eye Contact Lens. 2008 Jul;34(4):224-8. doi: 10.1097/ICL.0b013e318165d501.
To investigate the changes in corneal shape and optical performance during and after discontinuation of overnight orthokeratology for correction of myopia.
Both eyes of 15 subjects were fitted with overnight reverse-geometry orthokeratology lenses, which were then worn for >4 hr overnight for 52 weeks. Subjects were free of ocular disease and had a corrected visual acuity of > or =1.0. Refractive correction, uncorrected visual acuity, corneal topography, and contrast sensitivity (at 4 spatial frequencies) were measured under photopic conditions.
Refractive error (spherical equivalent) and contrast sensitivity were decreased, whereas uncorrected visual acuity, the surface asymmetry index, and the surface regularity index were increased, 1 week after the onset of overnight orthokeratology and remained so during the 52 weeks of treatment. These parameters had largely returned to baseline values by 8 weeks after treatment discontinuation.
Overnight orthokeratology improved uncorrected visual acuity and reduced refractive error but increased corneal irregularity and impaired contrast sensitivity. However, these changes in visual function and corneal shape were reversed after discontinuation of orthokeratology lens wear.
研究在夜间角膜塑形术矫正近视过程中及停戴后角膜形态和光学性能的变化。
15名受试者的双眼均佩戴夜间反向几何角膜塑形镜,然后夜间佩戴超过4小时,持续52周。受试者无眼部疾病,矫正视力≥1.0。在明视条件下测量屈光矫正、未矫正视力、角膜地形图和(4个空间频率的)对比敏感度。
夜间角膜塑形术开始1周后,屈光不正(等效球镜度)和对比敏感度降低,而未矫正视力、表面不对称指数和表面规则性指数增加,且在52周的治疗期间一直如此。治疗停止8周后,这些参数基本恢复到基线值。
夜间角膜塑形术提高了未矫正视力,降低了屈光不正,但增加了角膜不规则性并损害了对比敏感度。然而,停戴角膜塑形镜后,视觉功能和角膜形态的这些变化得以逆转。