• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

The evaluation of hemodynamics in post thoracic esophagectomy patients.

作者信息

Oshima Kiyohiro, Kunimoto Fumio, Hinohara Hiroshi, Hayashi Yoshiro, Takeyoshi Izumi, Kuwano Hiroyuki

机构信息

Intensive Care Unit, Gunma University Hospital, 3-39-15 Showa-machi, Maebashi, Gunma 371-8511, Japan.

出版信息

Hepatogastroenterology. 2008 Jul-Aug;55(85):1338-41.

PMID:18795684
Abstract

BACKGROUND/AIMS: Thoracic esophagectomy is one of the most invasive operations, and it is necessary to have a precise understanding of postoperative hemodynamics in order to maintain normal circulation. PiCCO (pulse contour cardiac output, Pulsion Medical Systems; Munich, Germany), a new technique based on an arterial thermodilution technique, allows the measurement of intra-thoracic blood volume index (ITBVI), which has been reported to be a useful parameter for cardiac preload. In this study, changes of ITBVI were analyzed after thoracic esophagectomy using the PiCCO system. Simultaneously, the patient's circulating blood volume (cBV) and cardiac index (CI) were measured using dye densitometry and the relation between the CI and ITBVI was evaluated.

METHODOLOGY

The PiCCO system was introduced in 20 patients immediately after thoracic esophagectomy, and circulatory parameters such as central venous pressure (CVP), and ITBVI were measured on ICU Days (ICUD) 1, 2 and 3. cBV and CI were simultaneously measured using the Dye Densitogram (DDG) Analyzer System (Nihon Koden, Tokyo, Japan).

RESULTS

The mean fluid balance during the operation was 3462 +/- 1341mL. CI was 3.8 +/- 0.7L/min/m2 on ICUD 1, 4.4 +/- 0.8L/min/m2 on ICUD 2, and 4.3 +/- 1.OL/ min/m2 on ICUD 3, and postoperative hemodynamics were well maintained. The ITBVI (normal range: 850-1000mL/m2) was also well controlled with 977 +/- 216mL/m2 on ICUD 1, 1061 +/- 221mL/m2 on ICUD 2, and 1043 +/- 151mL/m2 on ICUD 3, respectively, although BV ratio (measured cBV / Japanese standard cBV based on height and weight) was less than 1.0 during the same period. Additionally, ITBVI had better correlation with CI (r = 0.559, p = 0.003) compared with CVP (r = 0.036, p = 0.861).

CONCLUSIONS

Following thoracic esophagectomy, ITBVI was maintained within the normal range, in spite of a decrease in cBV. There was a correlation between ITBVI and CI, indicating that ITBVI might be a useful parameter for cardiac preload.

摘要

相似文献

1
The evaluation of hemodynamics in post thoracic esophagectomy patients.
Hepatogastroenterology. 2008 Jul-Aug;55(85):1338-41.
2
Evaluation of respiratory status in patients after thoracic esophagectomy using PiCCO system.
Ann Thorac Cardiovasc Surg. 2008 Oct;14(5):283-8.
3
Does central venous pressure or pulmonary capillary wedge pressure reflect the status of circulating blood volume in patients after extended transthoracic esophagectomy?
J Anesth. 2005;19(1):21-5. doi: 10.1007/s00540-004-0282-0.
4
[Study on the effect of control mode of pressure and volume on cardiac index and intrathoracic blood volume index in critically ill patients].[压力与容量控制模式对危重症患者心脏指数和胸腔内血容量指数的影响研究]
Zhongguo Wei Zhong Bing Ji Jiu Yi Xue. 2009 Oct;21(10):593-6.
5
[Stress response of subarachnoid hemorrhage to cardiac performance and intravascular volume evaluated by the pulse contour cardiac output (PiCCO) system].
No Shinkei Geka. 2007 Feb;35(2):163-8.
6
The ability of PiCCO versus LiDCO variables to detect changes in cardiac index: a prospective clinical study.脉搏指示连续心输出量监测(PiCCO)与锂稀释连续心输出量监测(LiDCO)变量检测心脏指数变化的能力:一项前瞻性临床研究。
Minerva Anestesiol. 2008 Jul-Aug;74(7-8):367-74. Epub 2008 Apr 18.
7
Evaluation of the FloTrac uncalibrated continuous cardiac output system for perioperative hemodynamic monitoring after subarachnoid hemorrhage.蛛网膜下腔出血后围手术期血流动力学监测中FloTrac未校准连续心输出量系统的评估
J Neurosurg Anesthesiol. 2009 Jul;21(3):218-25. doi: 10.1097/ANA.0b013e3181a4cd8b.
8
[The PiCCO system with brachial-axillary artery access in hemodynamic monitoring during surgery of abdominal aortic aneurysm].[腹主动脉瘤手术中经肱腋动脉通路的脉波指示剂连续心输出量(PiCCO)系统用于血流动力学监测]
Minerva Anestesiol. 2001 Jun;67(6):447-56.
9
Pulse contour cardiac output system use in pediatric orthotopic liver transplantation: preliminary report of nine patients.
Transplant Proc. 2005 Sep;37(7):3168-70. doi: 10.1016/j.transproceed.2005.07.020.
10
Perioperative intra- and extravascular volume in liver transplant recipients.肝移植受者围手术期的血管内和血管外容量
Transplant Proc. 2011 May;43(4):1098-102. doi: 10.1016/j.transproceed.2011.03.022.

引用本文的文献

1
Transpulmonary thermodilution curves for detection of shunt.经肺温度稀释曲线用于检测分流。
Intensive Care Med. 2010 Jun;36(6):1083-6. doi: 10.1007/s00134-010-1876-7. Epub 2010 Apr 16.