Suppr超能文献

[双嘧达莫静脉注射联合低水平运动负荷的铊-201心肌单光子发射计算机断层扫描对缺血性心脏病的诊断价值——与同一患者极量运动负荷单光子发射计算机断层扫描图像的比较]

[Usefulness of thallium-201 myocardial SPECT using dipyridamole infusion combined with low level exercise for the detection of the ischemic heart disease--comparison with SPECT images by maximum physical exercise in the same patients].

作者信息

Takao Y, Murata H, Katoh K, Onoguchi M, Ohtake E, Cho K

机构信息

Division of Nuclear Medicine, Toranomon Hospital, Tokyo, Japan.

出版信息

Kaku Igaku. 1991 Apr;28(4):361-70.

PMID:1880970
Abstract

To evaluate the usefulness of thallium-201 myocardial SPECT using dipyridamole infusion combined with low level exercise (Dp-method) for the detection of the ischemic heart disease, we performed both Dp-method and maximum physical exercise SPECT (Ex-method) in the same 28 patients, and compared the results obtained by the two methods. In the visual evaluation, the detectability of each stenotic coronary territory by Dp-method tended to be higher than that by Ex-method (accuracy 71% vs 67%). The severity of the defect and the degree of the redistribution were higher by Dp-method than those by Ex-method. In the washout rate (WR) analysis in 14 angina pectoris patients, the detectability (accuracy) by Dp-method was significantly higher than that by Ex-method (86% vs 64%; p less than 0.05). In comparison of mean WR values in normal subjects (10 cases for Dp-method and other 8 cases for Ex-method), mean WR by Dp-method was as high as that by Ex-method and the deviation of WR value among subjects was very small. This was probably due to the effect of the low level exercise. These results suggested that Dp-method was more excellent than Ex-method in the evaluation of the ischemic heart disease, and was a useful method of the daily routine work. The incidence of chest symptom and the electrocardiographic ST-depression was as high by Dp-method as that by Ex-method. The filling defects in Dp-method were thought to be induced not only by the difference in the relative increase of the myocardial perfusion, but also by the myocardial ischemia.

摘要

为评估双嘧达莫静脉输注联合低水平运动的铊-201心肌单光子发射计算机断层扫描(双嘧达莫法)在检测缺血性心脏病中的应用价值,我们对28例患者同时进行了双嘧达莫法和最大量体力运动单光子发射计算机断层扫描(运动法),并比较了两种方法的结果。在视觉评估中,双嘧达莫法对各狭窄冠状动脉区域的检测能力倾向于高于运动法(准确率71%对67%)。双嘧达莫法的缺损严重程度和再分布程度高于运动法。在14例心绞痛患者的洗脱率(WR)分析中,双嘧达莫法的检测能力(准确率)显著高于运动法(86%对64%;P<0.05)。比较正常受试者的平均WR值(双嘧达莫法10例,运动法8例),双嘧达莫法的平均WR与运动法相当,受试者间WR值的偏差非常小。这可能是由于低水平运动的影响。这些结果表明,在评估缺血性心脏病方面,双嘧达莫法比运动法更优越,是日常工作中一种有用的方法。双嘧达莫法引起的胸部症状发生率和心电图ST段压低与运动法一样高。双嘧达莫法中的充盈缺损被认为不仅是由心肌灌注相对增加的差异引起的,也是由心肌缺血引起的。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验