Suppr超能文献

一种用于超极化氦-3磁共振成像与肺部X射线计算机断层扫描图像融合的图像采集与配准策略。

An image acquisition and registration strategy for the fusion of hyperpolarized helium-3 MRI and x-ray CT images of the lung.

作者信息

Ireland Rob H, Woodhouse Neil, Hoggard Nigel, Swinscoe James A, Foran Bernadette H, Hatton Matthew Q, Wild Jim M

机构信息

Academic Units of Radiology and Clinical Oncology, University of Sheffield, Sheffield, UK.

出版信息

Phys Med Biol. 2008 Nov 7;53(21):6055-63. doi: 10.1088/0031-9155/53/21/011. Epub 2008 Oct 9.

Abstract

The purpose of this ethics committee approved prospective study was to evaluate an image acquisition and registration protocol for hyperpolarized helium-3 magnetic resonance imaging ((3)He-MRI) and x-ray computed tomography. Nine patients with non-small cell lung cancer (NSCLC) gave written informed consent to undergo a free-breathing CT, an inspiration breath-hold CT and a 3D ventilation (3)He-MRI in CT position using an elliptical birdcage radiofrequency (RF) body coil. (3)He-MRI to CT image fusion was performed using a rigid registration algorithm which was assessed by two observers using anatomical landmarks and a percentage volume overlap coefficient. Registration of (3)He-MRI to breath-hold CT was more accurate than to free-breathing CT; overlap 82.9 +/- 4.2% versus 59.8 +/- 9.0% (p < 0.001) and mean landmark error 0.75 +/- 0.24 cm versus 1.25 +/- 0.60 cm (p = 0.002). Image registration is significantly improved by using an imaging protocol that enables both (3)He-MRI and CT to be acquired with similar breath holds and body position through the use of a birdcage (3)He-MRI body RF coil and an inspiration breath-hold CT. Fusion of (3)He-MRI to CT may be useful for the assessment of patients with lung diseases.

摘要

这项经伦理委员会批准的前瞻性研究的目的是评估一种用于超极化氦 - 3磁共振成像(³He - MRI)和X射线计算机断层扫描的图像采集与配准方案。9例非小细胞肺癌(NSCLC)患者签署了书面知情同意书,接受自由呼吸CT、吸气屏气CT以及使用椭圆形鸟笼式射频(RF)体线圈在CT体位下进行的三维通气³He - MRI检查。³He - MRI与CT图像融合采用刚性配准算法,由两名观察者使用解剖标志和体积重叠百分比系数进行评估。³He - MRI与屏气CT的配准比与自由呼吸CT的配准更准确;重叠率分别为82.9±4.2%和59.8±9.0%(p < 0.001),平均标志误差分别为0.75±0.24 cm和1.25±0.60 cm(p = 0.002)。通过使用一种成像方案,即通过使用鸟笼式³He - MRI体RF线圈和吸气屏气CT,使³He - MRI和CT能够在相似的屏气和身体体位下采集,图像配准得到了显著改善。³He - MRI与CT的融合可能有助于评估肺部疾病患者。

相似文献

1
An image acquisition and registration strategy for the fusion of hyperpolarized helium-3 MRI and x-ray CT images of the lung.
Phys Med Biol. 2008 Nov 7;53(21):6055-63. doi: 10.1088/0031-9155/53/21/011. Epub 2008 Oct 9.
4
Hyperpolarized (3)He magnetic resonance imaging: comparison with four-dimensional x-ray computed tomography imaging in lung cancer.
Acad Radiol. 2012 Dec;19(12):1546-53. doi: 10.1016/j.acra.2012.08.007. Epub 2012 Sep 19.
5
Spatial Comparison of CT-Based Surrogates of Lung Ventilation With Hyperpolarized Helium-3 and Xenon-129 Gas MRI in Patients Undergoing Radiation Therapy.
Int J Radiat Oncol Biol Phys. 2018 Nov 15;102(4):1276-1286. doi: 10.1016/j.ijrobp.2018.04.077. Epub 2018 May 10.
7
Comparison of CT ventilation imaging and hyperpolarised gas MRI: effects of breathing manoeuvre.
Phys Med Biol. 2019 Mar 7;64(5):055013. doi: 10.1088/1361-6560/ab0145.
8
Lung ventilation volumetry with same-breath acquisition of hyperpolarized gas and proton MRI.
NMR Biomed. 2014 Dec;27(12):1461-7. doi: 10.1002/nbm.3187. Epub 2014 Sep 10.
10
Comparison of CT-based Lobar Ventilation with 3He MR Imaging Ventilation Measurements.
Radiology. 2016 Feb;278(2):585-92. doi: 10.1148/radiol.2015142278. Epub 2015 Aug 28.

引用本文的文献

1
Incorporation of Functional Lung Imaging Into Radiation Therapy Planning in Patients With Lung Cancer: A Systematic Review and Meta-Analysis.
Int J Radiat Oncol Biol Phys. 2024 Oct 1;120(2):370-408. doi: 10.1016/j.ijrobp.2024.04.001. Epub 2024 Apr 15.
2
Magnetic resonance imaging with hyperpolarized agents: methods and applications.
Phys Med Biol. 2017 Jul 7;62(13):R81-R123. doi: 10.1088/1361-6560/aa6be8. Epub 2017 Apr 6.
3
Functional imaging of the lungs with gas agents.
J Magn Reson Imaging. 2016 Feb;43(2):295-315. doi: 10.1002/jmri.25002. Epub 2015 Jul 27.
4
Regional ventilation changes in severe asthma after bronchial thermoplasty with (3)He MR imaging and CT.
Radiology. 2015 Jan;274(1):250-9. doi: 10.1148/radiol.14140080. Epub 2014 Aug 19.
6
Functional image-based radiotherapy planning for non-small cell lung cancer: A simulation study.
Radiother Oncol. 2009 Oct;93(1):32-6. doi: 10.1016/j.radonc.2009.05.018. Epub 2009 Jun 22.

本文引用的文献

1
Asymmetric quadrature split birdcage coil for hyperpolarized 3He lung MRI at 1.5T.
Magn Reson Med. 2008 Aug;60(2):431-8. doi: 10.1002/mrm.21664.
2
Automated breath-hold perfusion SPECT/CT fusion images of the lungs.
AJR Am J Roentgenol. 2007 Aug;189(2):455-63. doi: 10.2214/AJR.06.1290.
6
Preserving functional lung using perfusion imaging and intensity-modulated radiation therapy for advanced-stage non-small cell lung cancer.
Int J Radiat Oncol Biol Phys. 2007 Aug 1;68(5):1349-58. doi: 10.1016/j.ijrobp.2007.02.015. Epub 2007 Apr 18.
7
Reduction of normal lung irradiation in locally advanced non-small-cell lung cancer patients, using ventilation images for functional avoidance.
Int J Radiat Oncol Biol Phys. 2007 Jun 1;68(2):562-71. doi: 10.1016/j.ijrobp.2007.01.044. Epub 2007 Mar 29.
9
A methodology for using SPECT to reduce intensity-modulated radiation therapy (IMRT) dose to functioning lung.
Int J Radiat Oncol Biol Phys. 2006 Dec 1;66(5):1543-52. doi: 10.1016/j.ijrobp.2006.07.1377.
10
The management of respiratory motion in radiation oncology report of AAPM Task Group 76.
Med Phys. 2006 Oct;33(10):3874-900. doi: 10.1118/1.2349696.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验