Ireland Rob H, Woodhouse Neil, Hoggard Nigel, Swinscoe James A, Foran Bernadette H, Hatton Matthew Q, Wild Jim M
Academic Units of Radiology and Clinical Oncology, University of Sheffield, Sheffield, UK.
Phys Med Biol. 2008 Nov 7;53(21):6055-63. doi: 10.1088/0031-9155/53/21/011. Epub 2008 Oct 9.
The purpose of this ethics committee approved prospective study was to evaluate an image acquisition and registration protocol for hyperpolarized helium-3 magnetic resonance imaging ((3)He-MRI) and x-ray computed tomography. Nine patients with non-small cell lung cancer (NSCLC) gave written informed consent to undergo a free-breathing CT, an inspiration breath-hold CT and a 3D ventilation (3)He-MRI in CT position using an elliptical birdcage radiofrequency (RF) body coil. (3)He-MRI to CT image fusion was performed using a rigid registration algorithm which was assessed by two observers using anatomical landmarks and a percentage volume overlap coefficient. Registration of (3)He-MRI to breath-hold CT was more accurate than to free-breathing CT; overlap 82.9 +/- 4.2% versus 59.8 +/- 9.0% (p < 0.001) and mean landmark error 0.75 +/- 0.24 cm versus 1.25 +/- 0.60 cm (p = 0.002). Image registration is significantly improved by using an imaging protocol that enables both (3)He-MRI and CT to be acquired with similar breath holds and body position through the use of a birdcage (3)He-MRI body RF coil and an inspiration breath-hold CT. Fusion of (3)He-MRI to CT may be useful for the assessment of patients with lung diseases.
这项经伦理委员会批准的前瞻性研究的目的是评估一种用于超极化氦 - 3磁共振成像(³He - MRI)和X射线计算机断层扫描的图像采集与配准方案。9例非小细胞肺癌(NSCLC)患者签署了书面知情同意书,接受自由呼吸CT、吸气屏气CT以及使用椭圆形鸟笼式射频(RF)体线圈在CT体位下进行的三维通气³He - MRI检查。³He - MRI与CT图像融合采用刚性配准算法,由两名观察者使用解剖标志和体积重叠百分比系数进行评估。³He - MRI与屏气CT的配准比与自由呼吸CT的配准更准确;重叠率分别为82.9±4.2%和59.8±9.0%(p < 0.001),平均标志误差分别为0.75±0.24 cm和1.25±0.60 cm(p = 0.002)。通过使用一种成像方案,即通过使用鸟笼式³He - MRI体RF线圈和吸气屏气CT,使³He - MRI和CT能够在相似的屏气和身体体位下采集,图像配准得到了显著改善。³He - MRI与CT的融合可能有助于评估肺部疾病患者。