Abe Chikara, Tashiro Takayuki, Tanaka Kunihiko, Ogihara Ryousuke, Morita Hironobu
Department of Physiology, Gifu University Graduate School of Medicine, Gifu, Japan.
J Pharmacol Toxicol Methods. 2009 Jan-Feb;59(1):7-12. doi: 10.1016/j.vascn.2008.09.002. Epub 2008 Sep 22.
The iPRECIO (Primetech Corporation, Tokyo, Japan) is a new form of pump for infusing small laboratory animals. The key features of the iPRECIO are that it can be implanted within the animal, it is refillable, and it is programmable. The infusion start-points and end-points are adjustable, infusion rate can be altered, and the infusion solution can be changed after the pump is implanted. In order to confirm the precision of the iPRECIO, in vivo and in vitro experiments were employed.
In the in vitro experiment, at the excretion rate of 1 microl/h for 336 h, 15 microl/h for 96 h, and 30 microl/h for 120 h, the decrease in each pump weight was used to estimate the actual excretion volume. In the in vivo experiments, the iPRECIO was chronically implanted in rats, angiotensin II was infused, and arterial pressure (AP) was monitored.
In the in vitro experiment, the volume of solution excreted from the pump increased with time, and the volume excreted matched the programmed volume. The infusion rate also changed at the scheduled time. In the in vivo experiment, AP increased and decreased on schedule, and a dose-dependent pressor response to angiotensin II occurred. Furthermore, after exchanging saline with angiotensin II, AP increased and decreased on schedule.
Present data of the in vitro and in vivo experiments indicates that the iPRECIO worked precisely, making it suitable for a variety of experiments involving small laboratory animals.
iPRECIO(日本东京Primetech公司)是一种用于给小型实验动物输液的新型泵。iPRECIO的关键特性在于它可以植入动物体内、可重新填充且可编程。输液的起始点和终点可调,输液速率可以改变,并且在泵植入后可以更换输液溶液。为了确认iPRECIO的精度,进行了体内和体外实验。
在体外实验中,以1微升/小时的排泄速率持续336小时、15微升/小时持续96小时以及30微升/小时持续120小时,通过各泵重量的减少来估算实际排泄量。在体内实验中,将iPRECIO长期植入大鼠体内,输注血管紧张素II,并监测动脉血压(AP)。
在体外实验中,从泵中排泄出的溶液体积随时间增加,且排泄体积与编程体积相符。输液速率也在预定时间发生变化。在体内实验中,动脉血压按计划升高和降低,并且对血管紧张素II出现了剂量依赖性升压反应。此外,在用血管紧张素II替换生理盐水后,动脉血压按计划升高和降低。
目前体外和体内实验的数据表明,iPRECIO工作精确,使其适用于涉及小型实验动物的各种实验。