Yip Leonard W, Mikelberg Frederick S
Department of Ophthalmology and Visual Sciences, University of British Columbia, Vancouver, Canada.
J Glaucoma. 2008 Oct-Nov;17(7):513-6. doi: 10.1097/IJG.0b013e31815f5332.
To compare the performance of the Glaucoma Probability Score (GPS), Mikelberg linear discriminant function (LDF), Burk LDF, and Moorfield regression analysis (MRA) in classifying optic disc images acquired from normals and glaucoma patients with the Heidelberg Retina Tomograph (HRT).
This is a retrospective comparative study of 110 eyes of 110 subjects clinically categorized as glaucoma or normal. Topographic images of the optic nerve head were obtained from HRT. Data analysis of the HRT images were carried out using GPS, Mikelberg LDF, Burk LDF, and MRA. Diagnostic performances and agreement in classification between the data analysis tools were calculated and compared for GPS, Mikelberg LDF, Burk LDF, and MRA.
The highest specificity but lowest sensitivity value was obtained using the Burk LDF. The highest sensitivity but lowest specificity was obtained using the GPS. The GPS and MRA were however similar in performance. Sensitivity and specificity values of the GPS and other LDFs were affected by disc size.
The GPS compared similarly with the MRA without the need of additional contour line placements. Disc size is still an important factor in classification by the GPS and the other LDFs.
比较青光眼概率评分(GPS)、米克尔伯格线性判别函数(LDF)、伯克LDF和摩尔菲尔德回归分析(MRA)在使用海德堡视网膜断层扫描仪(HRT)对正常人和青光眼患者的视盘图像进行分类时的性能。
这是一项对110名临床分类为青光眼或正常的受试者的110只眼睛进行的回顾性比较研究。从HRT获取视神经乳头的地形图图像。使用GPS、米克尔伯格LDF、伯克LDF和MRA对HRT图像进行数据分析。计算并比较了GPS、米克尔伯格LDF、伯克LDF和MRA在数据分析工具之间的诊断性能和分类一致性。
使用伯克LDF获得了最高的特异性但最低的敏感性值。使用GPS获得了最高的敏感性但最低的特异性。然而,GPS和MRA在性能上相似。GPS和其他LDF的敏感性和特异性值受视盘大小的影响。
GPS与MRA相比性能相似,无需额外放置轮廓线。视盘大小仍然是GPS和其他LDF分类中的一个重要因素。