Suppr超能文献

皮肤阻抗测量在针灸研究中的应用:连续记录系统的研制。

Skin impedance measurements for acupuncture research: development of a continuous recording system.

机构信息

National College of Natural Medicine, 049 SW Porter St, Portland, OR 97201 USA. Tel.: 1-503-552-1745;

出版信息

Evid Based Complement Alternat Med. 2008 Dec;5(4):443-50. doi: 10.1093/ecam/nem060. Epub 2007 Jun 15.

Abstract

Skin impedance at acupuncture points (APs) has been used as a diagnostic/therapeutic aid for more than 50 years. Currently, researchers are evaluating the electrophysiologic properties of APs as a possible means of understanding acupuncture's mechanism. To comprehensively assess the diagnostic, therapeutic and mechanistic implications of acupuncture point skin impedance, a device capable of reliably recording impedances from 100 kOmega to 50 MOmega at multiple APs over extended time periods is needed. This article describes design considerations, development and testing of a single channel skin impedance system (hardware, control software and customized electrodes). The system was tested for accuracy against known resistors and capacitors. Two electrodes (the AMI and the ORI) were compared for reliability of recording over 30 min. Two APs (LU 9 and PC 6) and a nearby non-AP site were measured simultaneously in four individuals for 60 min. Our measurement system performed accurately (within 5%) against known resistors (580 kOmega-10 MOmega) and capacitors (10 nF-150 nF). Both the AMI electrode and the modified ORI electrode recorded skin impedance reliably on the volar surface of the forearm (r = 0.87 and r = 0.79, respectively). In four of four volunteers tested, skin impedance at LU 9 was less than at the nearby non-AP site. In three of four volunteers skin impedance was less at PC 6 than at the nearby non-AP site. We conclude that our system is a suitable device upon which we can develop a fully automated multi-channel device capable of recording skin impedance at multiple APs simultaneously over 24 h.

摘要

穴位皮肤阻抗(APs)已被用作诊断/治疗辅助手段超过 50 年。目前,研究人员正在评估 APs 的电生理特性,作为理解针灸机制的一种可能手段。为了全面评估穴位皮肤阻抗的诊断、治疗和机制意义,需要一种能够在多个 APs 上可靠记录 100 kΩ 至 50 MOmega 范围内的阻抗并具有长时间扩展能力的设备。本文描述了一种单通道皮肤阻抗系统(硬件、控制软件和定制电极)的设计考虑、开发和测试。该系统针对已知电阻器和电容器进行了准确性测试。两种电极(AMI 和 ORI)在 30 分钟以上的时间内记录可靠性进行了比较。在四名个体中,同时测量了两个穴位(LU 9 和 PC 6)和附近的非穴位部位 60 分钟。我们的测量系统对已知电阻器(580 kΩ-10 MOmega)和电容器(10 nF-150 nF)的测量精度在 5%以内。AMI 电极和改良后的 ORI 电极都能够可靠地记录前臂掌侧的皮肤阻抗(r = 0.87 和 r = 0.79)。在四名志愿者的测试中,LU 9 处的皮肤阻抗均小于附近的非穴位部位。在四名志愿者中,有三人的 PC 6 处皮肤阻抗均小于附近的非穴位部位。我们得出结论,我们的系统是一种合适的设备,我们可以在此基础上开发一种能够在 24 小时内同时记录多个 APs 皮肤阻抗的全自动多通道设备。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验