Abstract

OBJECTIVE

To evaluate the monitoring of ultrasonography in artificial vascular graft for arteriovenous fistula and its complications in patients with chronic renal failure.

METHODS

Eighteen cases of artificial vascular graft arteriovenous fistula after four to six weeks were enrolled. The diameter, the peak velocity and blood flow were examined in arterial fistula. And the artificial vascular diameter, the peak velocity and blood flow of artificial vessels next to artery were all examined and analyzed. And the patients with symptoms in the upper extremity were tested by ultrasound.

RESULTS

Intravascular blood showed good filling in fistula and artificial blood vessels in four to six weeks after artificial vascular graft for arteriovenous fistula by color doppler ultrasonography. The arterial fistula diameter, the peak velocity and blood flow were (3.61 +/- 0.68) mm and (298.56 +/- 93.42) cm/s and (583.62 +/- 216.77) ml/min. Artificial vascular diameter in (4.47 +/- 0.61) mm, the peak velocity and blood flow were (219.37 +/- 68.42) cm/s and (325.23 +/- 117.12) ml/min in the artificial blood vessels next to artery. Seven patients with upper extremity discomfort were examined by ultrasonography. One case was serum swollen. Three cases were thrombosis in artificial vessels. One case was pseudoaneurysm. Two cases were edema.

CONCLUSIONS

Ultrasonography plays a significant clinic role in testing artificial vascular graft for arteriovenous fistula and its complications.

摘要

目的

评估超声监测在慢性肾衰竭患者动静脉内瘘人工血管移植及其并发症中的应用。

方法

纳入18例人工血管移植动静脉内瘘术后4至6周的患者。检测动脉内瘘的直径、峰值流速和血流量。同时检测并分析人工血管直径、动脉旁人工血管的峰值流速和血流量。对上肢有症状的患者进行超声检查。

结果

彩色多普勒超声显示,人工血管移植动静脉内瘘术后4至6周,瘘管和人工血管内血液充盈良好。动脉内瘘直径、峰值流速和血流量分别为(3.61±0.68)mm、(298.56±93.42)cm/s和(583.62±216.77)ml/min。动脉旁人工血管直径为(4.47±0.61)mm,峰值流速和血流量分别为(219.37±68.42)cm/s和(325.23±117.12)ml/min。对7例上肢不适患者进行超声检查。1例为血清肿。3例为人工血管内血栓形成。1例为假性动脉瘤。2例为水肿。

结论

超声在检测动静脉内瘘人工血管移植及其并发症方面具有重要的临床作用。