Jaber A M, Moody G J, Thomas J D, Willcox A
Chemistry Department, UWIST, Cardiff, Wales UK.
Talanta. 1977 Oct;24(10):655-7. doi: 10.1016/0039-9140(77)80115-x.
Radiotracer studies with (45)Ca, (89)Sr and (133)Ba have provided evidence that the permeation of magnesium, strontium and barium ions through PVC membranes containing Orion 92-20-02 liquid ion-exchanger is inhibited by their low affinity for the liquid ion-exchanger sites. Experiments with (7)Be indicate a strong affinity of the membrane for beryllium ions with corresponding inhibition of permeation. When acid is present in the solution on one side of the membrane, preferential permeation by protons may lead to transport of ions against their concentration gradient in order to maintain the balance of charge.