Kim Sooah, Jacob Jason S, Kim Danny C, Rivera Rafael, Lim Ruth P, Lee Vivian S
Department of Radiology, New York University Medical Center, New York, New York 10016, USA.
J Magn Reson Imaging. 2008 Nov;28(5):1293-8. doi: 10.1002/jmri.21567.
To determine the feasibility of time-resolved dynamic contrast-enhanced magnetic resonance urography (MRU) for the evaluation of ureteral peristalsis using a data-sharing 3D gradient echo sequence with spiral k-space filling.
Eight patients (M=3, F=5, mean 48.1 years) were referred for MRU for the evaluation for renal mass (n=3), hematuria (n=2), urinary tract tuberculosis (n=1), postoperative bladder cancer (n=1), and postoperative ureteric reimplantation (n=1). Dynamic MRU was performed for 120 seconds at 1.5T after intravenous furosemide and gadolinium administration using an oblique sagittal, time-resolved T1 3D gradient echo sequence with 1 second effective temporal resolution. Study quality was assessed based on artifacts and extent of ureteric visualization. Frequency of peristalsis from the renal pelvis to urinary bladder was evaluated for each subject.
A total of 16 ureters were examined. Image quality was good in four ureters, satisfactory in 11 ureters, and poor in one ureter. Mean peristaltic frequency was 3.5 waves per minute (range, 2.5-6.5 waves/minute) in normal ureters (n=11). Five ureters were considered abnormal (one urinary tract tuberculosis and four postsurgical ureters), and all had decreased or no peristalsis (0-1.5 waves per minute).
MRU using a time-resolved, data-sharing 3D contrast-enhanced technique is able to demonstrate ureteral peristalsis and permits quantification of ureteral peristaltic frequency.
使用具有螺旋 k 空间填充的数据共享 3D 梯度回波序列,确定时间分辨动态对比增强磁共振尿路造影(MRU)评估输尿管蠕动的可行性。
8 例患者(男性 3 例,女性 5 例,平均年龄 48.1 岁)因肾肿块(3 例)、血尿(2 例)、泌尿系统结核(1 例)、膀胱癌术后(1 例)及输尿管再植术后(1 例)被转诊进行 MRU 检查。静脉注射速尿和钆剂后,在 1.5T 下使用具有 1 秒有效时间分辨率的斜矢状位、时间分辨 T1 3D 梯度回波序列进行 120 秒的动态 MRU 检查。根据伪影和输尿管可视化程度评估研究质量。评估每个受试者从肾盂到膀胱的蠕动频率。
共检查了 16 条输尿管。4 条输尿管图像质量良好,11 条输尿管图像质量满意,1 条输尿管图像质量差。正常输尿管(11 条)的平均蠕动频率为每分钟 3.5 次波动(范围为 2.5 - 6.5 次波动/分钟)。5 条输尿管被认为异常(1 例泌尿系统结核和 4 条术后输尿管),均出现蠕动减少或无蠕动(0 - 1.5 次波动/分钟)。
使用时间分辨、数据共享 3D 对比增强技术的 MRU能够显示输尿管蠕动,并允许对输尿管蠕动频率进行量化。