Holmes Warren A, Bock James J, Crill Brendan P, Koch Timothy C, Jones William C, Lange Andrew E, Paine Christopher G
Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Dr., Pasadena, California 91109, USA.
Appl Opt. 2008 Nov 10;47(32):5996-6008. doi: 10.1364/ao.47.005996.
We summarize the fabrication, flight qualification, and dark performance of bolometers completed at the Jet Propulsion Laboratory for the High Frequency Instrument (HFI) of the joint ESA/NASA Herschel/Planck mission to be launched in 2009. The HFI is a multicolor focal plane which consists of 52 bolometers operated at 100 mK. Each bolometer is mounted to a feedhorn-filter assembly which defines one of six frequency bands centered between 100-857 GHz. Four detectors in each of five bands from 143-857 GHz are coupled to both linear polarizations and thus measure the total intensity. In addition, eight detectors in each of four bands (100, 143, 217, and 353 GHz) couple only to a single linear polarization and thus provide measurements of the Stokes parameters, Q and U, as well as the total intensity. The measured noise equivalent power (NEP) of all detectors is at or below the background limit for the telescope and time constants are a few ms, short enough to resolve point sources as the 5 to 9 arc min beams move across the sky at 1 rpm.
我们总结了喷气推进实验室为将于2009年发射的欧洲航天局/美国国家航空航天局联合赫歇尔/普朗克任务的高频仪器(HFI)完成的测辐射热计的制造、飞行鉴定和暗性能。HFI是一个多色焦平面,由52个在100 mK下运行的测辐射热计组成。每个测辐射热计都安装在一个馈源喇叭-滤波器组件上,该组件定义了六个中心频率在100-857 GHz之间的频段之一。在143-857 GHz的五个频段中的每个频段的四个探测器都与两个线性极化耦合,从而测量总强度。此外,在四个频段(100、143、217和353 GHz)中的每个频段的八个探测器仅与单个线性极化耦合,从而提供斯托克斯参数Q和U以及总强度的测量值。所有探测器测得的噪声等效功率(NEP)处于或低于望远镜的背景极限,时间常数为几毫秒,短到足以在5至9弧分的波束以1转/分钟的速度扫过天空时分辨点源。