齿突螺钉粗细、长度及角度的枢椎解剖学研究。

Anatomical study of axis for odontoid screw thickness, length, and angle.

作者信息

Tun Kagan, Kaptanoglu Erkan, Cemil Berker, Yorubulut Mehmet, Karahan S Tuna, Tekdemir Ibrahim

机构信息

Department of Neurosurgery, Ankara Numune Education and Research Hospital, Samanpazari, 06550 Ankara, Turkey.

出版信息

Eur Spine J. 2009 Feb;18(2):271-5. doi: 10.1007/s00586-008-0814-7. Epub 2008 Nov 13.

Abstract

Anterior odontoid screw fixation is a safe and effective method for treatment of odontoid fractures. The screw treads should fit into the odontoid medulla, should pass the fracture line, and should pull fractured odontoid tip against body of axis in order to achieve optimum screw placement and treatment. This study has demonstrated optimal anterior odontoid screw thickness, length, and optimal angle for safe and strong anterior odontoid screw placement. Dry bone axis vertebrae were evaluated by direct measurements, X-ray measurements, and computerized tomography (CT) measurements. The screw thickness (inner diameter of the odontoid) was measured as well as screw length (distance between anterior-inferior point body of axis and tip of odontoid), and screw angle (the angle between basis of axis and tip of odontoid). The inner diameter of odontoid bone was measured as 6.5+/-1.9 mm, the screw length was 37.6+/-3.3 mm, and the screw angle was 62.4+/-4.7 on CT. There was no statistical difference between X-ray and CT in the measurements of screw thickness and angle. X-ray and CT measurements are both safe methods to determine the inner odontoid diameter and angle preoperatively. Screw length should be measured on CT only. To provide safe and strong anterior odontoid screw fixation, screw thickness, length, and angle should be known preoperatively, and these can be measured on X-ray and CT.

摘要

前路齿突螺钉固定术是治疗齿突骨折的一种安全有效的方法。螺钉螺纹应适配于齿突髓腔,穿过骨折线,并将骨折的齿突尖拉向枢椎体,以实现最佳的螺钉置入和治疗效果。本研究已证明了安全且稳固地进行前路齿突螺钉置入的最佳螺钉厚度、长度及最佳角度。通过直接测量、X线测量和计算机断层扫描(CT)测量对干燥的枢椎椎体进行评估。测量了螺钉厚度(齿突内径)、螺钉长度(枢椎体前下点与齿突尖之间的距离)以及螺钉角度(枢椎基底与齿突尖之间的角度)。CT测量显示齿突骨内径为6.5±1.9mm,螺钉长度为37.6±3.3mm,螺钉角度为62.4±4.7°。在螺钉厚度和角度测量方面,X线测量与CT测量之间无统计学差异。X线和CT测量均是术前确定齿突内径和角度的安全方法。螺钉长度仅应通过CT测量。为实现安全且稳固的前路齿突螺钉固定,术前应知晓螺钉厚度、长度和角度,这些均可通过X线和CT进行测量。

相似文献

1
Anatomical study of axis for odontoid screw thickness, length, and angle.
Eur Spine J. 2009 Feb;18(2):271-5. doi: 10.1007/s00586-008-0814-7. Epub 2008 Nov 13.
2
The three-dimensional morphometry of the odontoid peg and its impact on ventral screw osteosynthesis.
Bone Joint J. 2013 Apr;95-B(4):536-42. doi: 10.1302/0301-620X.95B4.30949.
3
[Anterior osteosynthesis of odontoid fractures].
Acta Chir Orthop Traumatol Cech. 2008 Oct;75(5):332-8.
5
6
Cement-augmented anterior odontoid screw fixation in elderly patients with odontoid fracture.
Clin Neurol Neurosurg. 2018 Dec;175:144-148. doi: 10.1016/j.clineuro.2018.11.005. Epub 2018 Nov 5.
9
Direct anterior fixation of odontoid fractures with a hollow spreading screw system.
Acta Neurochir (Wien). 1996;138(2):146-53. doi: 10.1007/BF01411353.

引用本文的文献

2
Feasibility of Anterior Fixation with Single Screw for Odontoid Fractures in Pediatrics: A Computed Tomographic Study.
Orthop Surg. 2023 Oct;15(10):2566-2573. doi: 10.1111/os.13834. Epub 2023 Aug 3.
3
Morphometric analysis of odontoid process among Arab population: a retrospective cone beam CT study.
PeerJ. 2023 May 23;11:e15411. doi: 10.7717/peerj.15411. eCollection 2023.
4
Morphometric parameters of the odontoid process of C2 vertebrae, in Indian population, a CT evaluation.
Surg Neurol Int. 2021 Sep 30;12:494. doi: 10.25259/SNI_417_2021. eCollection 2021.
5
Computerized Tomography-Based Morphometric Analysis of Odontoid in 100 Egyptian Patients.
Int J Spine Surg. 2020 Feb 29;14(1):59-65. doi: 10.14444/7008. eCollection 2020 Feb.
6
Morphometric Evaluation of Craniocervical Junction by Magnetic Resonance Imaging Method.
Asian J Neurosurg. 2019 Jul-Sep;14(3):702-709. doi: 10.4103/ajns.AJNS_293_17.
7
Anatomy of the dens and its implications for fracture treatment: an anatomical and radiological study.
Eur Spine J. 2019 Feb;28(2):317-323. doi: 10.1007/s00586-018-5793-8. Epub 2018 Oct 22.
9
Feasibility of anterior screw fixation in children: a tomographic study.
Eur Spine J. 2018 Jun;27(6):1388-1392. doi: 10.1007/s00586-018-5504-5. Epub 2018 Feb 9.
10
Biomechanical Comparison of Inter-fragmentary Compression Pressures: Lag Screw versus Herbert Screw for Anterior Odontoid Screw Fixation.
J Korean Neurosurg Soc. 2017 Sep;60(5):498-503. doi: 10.3340/jkns.2017.0202.011. Epub 2017 Aug 30.

本文引用的文献

2
Surgical treatment of acute type II and rostral type III odontoid fractures managed by anterior screw fixation.
South Med J. 2005 Sep;98(9):896-901. doi: 10.1097/01.smj.0000177342.81752.74.
3
Results of long-term follow-up in patients undergoing anterior screw fixation for type II and rostral type III odontoid fractures.
Spine (Phila Pa 1976). 2005 Mar 15;30(6):661-9. doi: 10.1097/01.brs.0000155415.89974.d3.
4
Management of acute odontoid fractures with single anterior screw fixation.
J Clin Neurosci. 2004 Nov;11(8):890-5. doi: 10.1016/j.jocn.2004.03.023.
5
Anterior instrumentation for traumatic C1-C2 instability.
Spine (Phila Pa 1976). 2003 Sep 1;28(17):E329-33. doi: 10.1097/01.BRS.0000083328.27907.3B.
7
Screw placement in transoral atlantoaxial plate systems: an anatomical study.
J Neurosurg. 2001 Jul;95(1 Suppl):80-7. doi: 10.3171/spi.2001.95.1.0080.
8
Spine update: cervical spine internal fixation using screw and screw-plate constructs.
Spine (Phila Pa 1976). 2000 Mar 1;25(5):643-52. doi: 10.1097/00007632-200003010-00020.
9
The reliability of the lateral radiograph in determination of the optimal transarticular C1-C2 screw length.
Spine (Phila Pa 1976). 1998 Oct 15;23(20):2190-4. doi: 10.1097/00007632-199810150-00009.
10
A clinical comparison of one- and two-screw odontoid fixation.
J Neurosurg. 1998 Sep;89(3):366-70. doi: 10.3171/jns.1998.89.3.0366.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验