Suppr超能文献

印度西部成年人淋巴细胞亚群的参考范围:性别、年龄和计数方法的影响。

Reference ranges for lymphocyte subsets in adults from western India: influence of sex, age and method of enumeration.

作者信息

Das Bibhu R, Bhanushali Aparna A, Khadapkar R, Jeswani Kanchan D, Bhavsar Mita, Dasgupta A

机构信息

Research and Development, SRL Ranbaxy Ltd, Plot No 113, MIDC,15th Street, Andheri (East), Mumbai-400 093, India.

出版信息

Indian J Med Sci. 2008 Oct;62(10):397-406.

Abstract

BACKGROUND

The enumeration of absolute CD4 counts is of primary importance, since therapeutic protocols for HIV1 patients are based on these.

AIMS

To establish reference ranges for the CD4 and CD8 T-lymphocytes in the Indian population.

SETTINGS AND DESIGN

Enumeration of absolute numbers and percentages of lymphocyte subsets was performed in 252 healthy adult Indians.

METHODS AND MATERIALS

The assays for SPT were carried out using the Beckman EPICS XL-MCL flow cytometer and the cytostat tetraCHROME reagent containing CD45/CD8/CD4/CD3 monoclonal antibodies. For comparison with DPT the absolute lymphocyte count was obtained using the Coulter STK-S fully automated hematology analyzer.

STATISTICAL ANALYSIS

Regression analysis and Students t test were used for data analysis.

RESULTS

Median values were as follows; absolute CD3 counts 1446 cells/mm3 (total), 1361 cells/mm3 (males) and 1511 cells/mm3 (females); absolute CD4 counts are 771 cells/mm3 (total), 705 cells/mm3 (males) and 839 cells/mm3 (females); absolute CD8 counts are 555 cells/mm3 (total), 552 cells/mm3 (males) and 561 cells/mm3 (females). The median CD4/CD8 ratio for the total samples was 1.34, for males 1.22 and for females 1.49.

CONCLUSIONS

In this study we have established reference ranges for normal Indian adults using the fully automated Single Platform Technology. The lymphocyte subsets values of our population are closer to those of the population from Botswana and China rather than the Western population. The absolute CD3 and CD4 counts and the CD4:CD8 ratio are higher in females than in males. Consistently higher values are obtained by the DPT as compared to the SPT.

摘要

背景

绝对CD4细胞计数的测定至关重要,因为针对HIV-1患者的治疗方案基于此。

目的

确定印度人群中CD4和CD8 T淋巴细胞的参考范围。

研究背景与设计

对252名健康成年印度人进行淋巴细胞亚群绝对数量和百分比的测定。

方法与材料

使用贝克曼EPICS XL-MCL流式细胞仪和含CD45/CD8/CD4/CD3单克隆抗体的细胞染色四色试剂进行淋巴细胞亚群检测。为与双平台技术(DPT)比较,使用库尔特STK-S全自动血液分析仪获得绝对淋巴细胞计数。

统计分析

采用回归分析和学生t检验进行数据分析。

结果

中位数如下:绝对CD3细胞计数,总体为1446个细胞/mm³,男性为1361个细胞/mm³,女性为1511个细胞/mm³;绝对CD4细胞计数,总体为771个细胞/mm³,男性为705个细胞/mm³,女性为839个细胞/mm³;绝对CD8细胞计数,总体为555个细胞/mm³,男性为552个细胞/mm³,女性为561个细胞/mm³。总样本的CD4/CD8中位数比值为1.34,男性为1.22,女性为1.49。

结论

在本研究中,我们使用全自动单平台技术建立了正常印度成年人的参考范围。我们人群的淋巴细胞亚群值更接近博茨瓦纳和中国人群,而非西方人群。女性的绝对CD3和CD4细胞计数以及CD4:CD8比值高于男性。与单平台技术(SPT)相比,双平台技术(DPT)获得的值始终更高。