Abstract

PURPOSE

Sealing the lymphatic vessels during abdominal and pelvic surgery is important to prevent the leakage of lymphatic fluid and its resultant sequelae. To our knowledge we compared for the first time the quality of lymphatic sealing by each of 4 commonly used laparoscopic dissection devices.

MATERIALS AND METHODS

A total of 12 domestic pigs were used to test dissecting devices, including monopolar scissors (Ethicon Endo-Surgery, Cincinnati, Ohio), Harmonic ACE Scalpel, LigaSure V, EnSeal and Trissector. A midline incision was made from mid sternum to umbilicus, the diaphragm was divided and the porcine thoracic duct was isolated. In all animals each device was used to seal an area of the duct and each seal was placed at least 2 cm from the prior seal. In group 1 the thoracic duct of 6 pigs was cannulated with a 5Fr catheter and the seal was subjected to burst pressure testing using a burst pressure measuring device (Cole-Parmer, Vernon Hills, Illinois). In the 6 pigs in group 2 each seal was immediately sent for histopathological evaluation. Specimens were given a score for the extent of cautery damage, including 0-none, 1-minimal, 2-moderate, 3-severe and 4-extreme.

RESULTS

A total of 64 seals were created, of which 35 were subjected to burst pressure testing. Mean size of the thoracic duct was 2.6 mm. No acute seal failures were observed with any bipolar device or the harmonic shears. However, 2 immediate failures (33%) were seen with monopolar scissors. Mean burst pressure for monopolar scissors, Harmonic ACE Scalpel, LigaSure V, EnSeal and Trissector was 46 (range 0 to 165), 540 (range 175 to 795), 258 (range 75 to 435), 453 (range 255 to 825) and 379 mm Hg (range 175 to 605), respectively (p <0.05). Trissector, Harmonic ACE Scalpel and EnSeal generated seals with significantly higher burst pressure than that of monopolar scissors (p <0.05). Histopathological evaluation revealed that LigaSure caused less thermal damage than Trissector and EnSeal (p <0.05).

CONCLUSIONS

Each device tested except monopolar scissors consistently produced a supraphysiological seal and should be suitable for sealing lymphatic vessels during laparoscopic surgery.

摘要

目的

在腹部和盆腔手术中封闭淋巴管对于预防淋巴液渗漏及其继发后遗症至关重要。据我们所知,我们首次比较了4种常用腹腔镜解剖器械各自的淋巴管封闭质量。

材料与方法

总共使用12头家猪来测试解剖器械,包括单极剪刀(美国强生公司爱惜康内镜外科部,俄亥俄州辛辛那提)、超声刀ACE、LigaSure V、EnSeal和Trissector。在胸骨中部至脐部做正中切口,切开膈肌并分离猪的胸导管。在所有动物中,每种器械都用于封闭一段胸导管,且每个封闭部位与之前的封闭部位至少相距2 cm。在第1组的6头猪中,用一根5Fr导管插入胸导管,使用爆破压力测量装置(美国科尔帕默仪器公司,伊利诺伊州弗农山)对封闭部位进行爆破压力测试。在第2组的6头猪中,每个封闭部位立即送去进行组织病理学评估。标本根据烧灼损伤程度进行评分,包括0分 - 无损伤、1分 - 轻度、2分 - 中度、3分 - 重度和4分 - 极重度。

结果

共创建了64个封闭部位,其中35个进行了爆破压力测试。胸导管的平均直径为2.6 mm。使用任何双极器械或超声刀均未观察到急性封闭失败。然而,使用单极剪刀出现了2次即刻失败(33%)。单极剪刀、超声刀ACE、LigaSure V、EnSeal和Trissector的平均爆破压力分别为46(范围0至165)、540(范围175至795)、258(范围75至435)、453(范围255至825)和379 mmHg(范围175至605)(p <0.05)。Trissector、超声刀ACE和EnSeal产生的封闭部位爆破压力明显高于单极剪刀(p <0.05)。组织病理学评估显示,LigaSure造成的热损伤比Trissector和EnSeal少(p <0.05)。

结论

除单极剪刀外,所测试的每种器械均能持续产生超生理状态的封闭效果,应适用于腹腔镜手术中封闭淋巴管。