Suppr超能文献

高能光子放疗中门静脉片图像质量的改善。

Improved portal film image quality in radiation therapy with high energy photons.

作者信息

Kihlén B, Cederlund T, Lagergren C, Nordell B, Rudén B I

机构信息

Department of Oncology, Karolinska Hospital, Stockholm, Sweden.

出版信息

Acta Oncol. 1991;30(3):369-73. doi: 10.3109/02841869109092388.

Abstract

Various metal screen-film combinations have been investigated in order to determine the best radiographic image. The quality of these different combinations has been evaluated by measuring the scattered to primary film dose ratio S/P. The S/P ratio increases with increasing atomic number of the front screen for 4 MV x-rays but shows no significant difference for 8 MV x-rays. For rear screens the S/P ratio is slightly increased for higher atomic numbers. A metal with an atomic number around 26-29 should be an optimal metal screen regarding quality aspects. A cassette of stainless steel has, in clinical use for portal and/or verification films, given very good images.

摘要

为了确定最佳的射线照相图像,已经对各种金属屏-片组合进行了研究。通过测量散射剂量与一次射线胶片剂量之比S/P来评估这些不同组合的质量。对于4兆伏的X射线,S/P比值随着前屏原子序数的增加而增加,但对于8兆伏的X射线则没有显著差异。对于后屏,较高原子序数的S/P比值略有增加。就质量方面而言,原子序数在26 - 29左右的金属应该是最佳的金属屏。不锈钢暗盒在临床用于射野和/或验证片时,能提供非常好的图像。